Skip to product information
1 of 1
AMETEK MOCON →

Dansensor® ISM-3i Oxygen Sensor Module with Pressurized Tank

Dansensor® ISM-3i Oxygen Sensor Module with Pressurized Tank

SKU:PRO-5800b8

Accurate oxygen monitoring sensor module with high reliability & self-diagnostics.

Regular price $3,499.99
Regular price Sale price $3,499.99
Sale

Initiate Order

Dansensor® ISM-3i Oxygen Sensor Module with Pressurized Tank

Dansensor® ISM-3i Oxygen Sensor Module with Pressurized Tank

$3,499.99

Quantity: 1

Claim Your Seller Account

Dansensor® ISM-3i Oxygen Sensor Module with Pressurized Tank

Dansensor® ISM-3i Oxygen Sensor Module with Pressurized Tank

$3,499.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Dansensor® ISM-3i 230 Volts Sensor Module with Pressurized Tank is a highly accurate solution for monitoring oxygen levels in gas mixtures. Designed for low maintenance demand, this sensor module can be easily connected to a pressurized tank or utilized with the pump version for seamless sampling. With a measuring range from 1 ppm to 100%, self-diagnostics with alarm output, and high reliability exceeding ±1% accuracy, this module ensures precise monitoring. Its stainless steel construction, ceramic/solid-state O2 sensor, and compliance with industry-specific certifications make it an ideal choice for applications requiring stringent oxygen concentration control.

Product Specifications

Additional Information Additional Information
Optional sample kit for flow packaging machines (part number 270165)
Benefits Benefits
High reliability and accuracy- better than ± 1% of readingLow maintenance demandMeasuring range:1 ppm - 100% (std. 0-20,9%)Self diagnostics - monitoring of vital parameters with alarm output
Features Features
2 oxygen concentration alarmsSample gas supply by gas pressure or internal pump (specific instrument versions)Different set-up options for adaptation to the analyzer application0/4 - 20 mA as standard (optional: 0-10V if specified with the order)
Note Note
Specifications subject to change without notice. Further specifications are available in the User Guide.
Specifications Accuracy
± 1 Digit in Calibrated Range. | Better than ± 1 % of the Displayed Value
Specifications Alarms
Two O2 concentration alarm settings, system fault alarm (bad gas flow, sensor error, etc.)
Specifications Alternating Current Ac Voltage
230 V
Specifications Alternating Current Ac Voltage Tolerance
10 %
Specifications Built In Display
No
Specifications Cabinet Depth
125 mm
Specifications Cabinet Height
125 mm
Specifications Cabinet Material
Stainless Steel
Specifications Cabinet Width
185 mm
Specifications Calibration Intervals
12 m
Specifications Current Output
0/4 - 20 mA as standard (optional: 0-10V if specified with the order), scale can be defined by operator, i.e. 0-1%, 0-100 ppm.
Specifications Display Depth
20 mm
Specifications Display Height
96 mm
Specifications Display Width
96 mm
Specifications Frequency
50 Hz | 60 Hz
Specifications Maximum Alarm Output
48 V | 1 A
Specifications Measuring Range
1 to 100 %
Specifications Note For Alarm Output
Common, N.O. or N.C.
Specifications Note For Display
3 mm bezel for panel mounting.
Specifications Note For Measuring Range
Standard calibration 0-20.9%
Specifications Pressure
Yes
Specifications Pump
No
Specifications Remote Display
Yes
Specifications Sensor Flow
125 mL/min
Specifications Sensor Type
Ceramic | Solid State O2 Sensor
Specifications Signal Input
10 to 32 VDC external measuring control signal for start/stop of the analyzer.
Specifications Start Up Time
10 min
Specifications Weight
3.7 kg