Skip to product information
1 of 3
Scaletron Industries, Ltd. →

Scaletron Model 4040™ 60-Inch Digital Platform Scale

Scaletron Model 4040™ 60-Inch Digital Platform Scale

SKU:DRU-26588e

High-precision Scaletron platform scale with 0-5000 lb capacity, ±0.1% accuracy, and durable construction

Regular price $1,499.99
Regular price Sale price $1,499.99
Sale

Initiate Order

Scaletron Model 4040™ 60-Inch Digital Platform Scale

Scaletron Model 4040™ 60-Inch Digital Platform Scale

$1,499.99

Quantity: 1

Claim Your Seller Account

Scaletron Model 4040™ 60-Inch Digital Platform Scale

Scaletron Model 4040™ 60-Inch Digital Platform Scale

$1,499.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Scaletron Model 4040™ 60-Inch Digital Platform Scale is engineered for high-precision weighing, with a gross capacity range of 0 to 5000 lb (2268 kg) and an impressive accuracy of ±0.1%. Its robust steel construction and NEMA 4X, UL-approved enclosure ensure durability and protection from corrosion, making it ideal for frequent loading and unloading operations. The scale features a user-friendly LCD display for easy readability to 1 lb (kg) or 0.1 lb (kg), making it suitable for a wide range of industrial applications.

Product Specifications

Chemicals Chemicals
Scale is designed to accurately measure weight of alum, ammonia, caustic, fluoride, phosphate, polymers, sodium aluminate, sodium bisulfate, sodium hydroxide, sodium hypochlorite and other liquids or powders.
Digital Controllers Digital Controllers
Indicator/Controller Part Number - 3-1/2 DigitPlatform Size - 24" x 24", 30" x 30", 36" x 36", 48" x 48", 60" x 60", 72" x 72" - custom sizes availablePlatform Height - Bases 24", 30" & 36" - 3-1/2" (89 mm), bases 48" & larger - 5" (178 mm) - add 1/2" for bolt down feetGross Capacity - Up to 5000 lbs. (2268 kg) - custom capacities available (150% overload protection is provided)Accuracy - 0.5% of full capacityResolution - 0.1 up to 199.9, or 1.0 over 200 lbs. (kg)4 - 20 mA - Standard - scale or loop poweredLevel Indication/Relay Contacts - OptionalPower - 85 VAC to 265 VACEnclosure - NEMA 4X , UL Approved EnclosureShipping Weight - 24" x 24" = 130 lbs.; 30" x 30" = 150 lbs.; 36" x 36" = 160 lbs.; 48" x 48" = 240 lbs.Indicator/Controller Part Number - 4-1/2 DigitPlatform Size - 24" x 24", 30" x 30", 36" x 36", 48" x 48", 60" x 60", 72" x 72" - custom sizes availablePlatform Height - Bases 24", 30" & 36" - 3-1/2" (89 mm), bases 48" & larger - 5" (178 mm) - add 1/2" for bolt down feetGross Capacity - Up to 5000 lbs. (2268 kg) - custom capacities available (150% overload protection is provided)Accuracy - 0.5% of full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4 - 20 mA - Standard - scale or loop poweredLevel Indication/Relay Contacts - (2) StandardPower - 120 VAC, 50/60 Hz, 0.3 A 240 VAC, 50/60 Hz, 0.15 AEnclosure - NEMA 4X , UL Approved EnclosureShipping Weight - 24" x 24" = 130 lbs.; 30" x 30" = 150 lbs.; 36" x 36" = 160 lbs.; 48" x 48" = 240 lbs.Indicator/Controller Part Number - 1020™Platform Size - 24" x 24", 30" x 30", 36" x 36", 48" x 48", 60" x 60", 72" x 72" - custom sizes availablePlatform Height - Bases 24", 30" & 36" - 3-1/2" (89 mm), bases 48" & larger - 5" (178 mm) - add 1/2" for bolt down feetGross Capacity - Up to 5000 lbs. (2268 kg) - custom capacities available (150% overload protection is provided)Accuracy - 0.1% - 0.25% full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4 - 20 mA - Standard on Channel 1, Optional on Channel 2 - loop poweredLevel Indication/Relay Contacts - Optional - Up to 4 (as high or low) on one channel or more than one per channel for a total of 4 set points with relay contractPower - 85 VAC to 265 VACEnclosure - NEMA 4X , UL Approved EnclosureShipping Weight - 24" x 24" = 130 lbs.; 30" x 30" = 150 lbs.; 36" x 36" = 160 lbs.; 48" x 48" = 240 lbs.Indicator/Controller Part Number - 1099™C.P.C.Platform Size - 24" x 24", 30" x 30", 36" x 36", 48" x 48", 60" x 60", 72" x 72" - custom sizes availablePlatform Height - Bases 24", 30" & 36" - 3-1/2" (89 mm), bases 48" & larger - 5" (178 mm) - add 1/2" for bolt down feetGross Capacity - Up to 5000 lbs. (2268 kg) - custom capacities available (150% overload protection is provided)Accuracy - 0.1% - 0.25% full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4-20 mA - Standard on Channel 1 - loop powered (available for Channels 2 thru 4)Level Indication/Relay Contacts - Optional - Up to 4 (as high or low) on one channel or more than one per channel for a total of 4 set points with relay contractPower - 85 VAC to 265 VACEnclosure - NEMA 4X , UL Approved EnclosureShipping Weight - 24" x 24" = 130 lbs.; 30" x 30" = 150 lbs.; 36" x 36" = 160 lbs.; 48" x 48" = 240 lbs.
Options Options
240 VAC power (4-1/2 digit display)4-1/2 digit display with active and passive 4 - 20 mA, 0 - 20 mA, and -8 to +12 mA, and two adjustable low level contactsModel 1020™ 5 digit controller with loop powered 4 - 20 mA, up to four adjustable set points and one or two channelsModel 1099™ Chemical Process ControllerRemote mounting of indicator box up to 200 feet (61 meters) awayJunction box - Additional length of wire cable
Specifications Accuracy
0.1
Specifications Alternating Current Ac Voltage
240 V
Specifications Base Sizes
60 in
Specifications Conductor Wire Cable Size
20 ft
Specifications Enclosure
National Electrical Manufacturer Association (NEMA) 4X | Underwriters Laboratories (UL) Approved
Specifications Gross Capacity Range
0 to 5000 lb | 2268 kg
Specifications Industry Standards
European Conformity (CE)
Specifications Number Of Conductors
4
Specifications Warranty
5 Years Full Warranty on All Products!
Specifications Weighing Properties Readout
Kilograms | Pounds
Standard Features Standard Features
Rugged steel construction protected by a corrosion resistant finish, with solid 1/2" PVC deckingAccommodates off-center loadsElectronic indicator housed in NEMA 4X, UL approved enclosure to provide protection from acidsNTEP stainless steel temperature compensated load cellSelf-locking tare adjustment knob4 - 20 mA output signal - scale or loop powered
Specifications Specifications
The Digital Platform Scale must have rugged steel frame that is zinc oxide primed and dry powder epoxy coated. The decking shall be solid, 1/2 inch thick PVC. All hardware shall be stainless steel. The height shall not exceed 3.5 inches (5 inches on 48" & larger bases) so as not to require a pit or ramp. Stainless steel leveling feet shall be supplied with 4 NTEP approved stainless steel shear beam cells. A four cell system is required for accurate reading so that off center loads may be placed anywhere on the base and still obtain an accurate reading.Scale shall be a Model 4040™ as manufactured by Scaletron™ Industries Ltd., Plumsteadville, PA.Standard Indicator3-1/2 Digit LCD Indicator: Indicator must be electronic with digital display with characters 0.5 inches high, with 0.1 lb. or 0.1 kg resolution and housed in a NEMA 4X, UL approved enclosure. Indicator is required to have 4 - 20 mA output selectable as scale powered or loop powered, standard. Indicator must have a knob to set tare weight. Accuracy is 0.5% of full scale, or better.Optional Indicators/Controllers4-1/2 Digit LED Indicator: Indicator must be electronic with digital display with characters 0.56 inches high and housed in a NEMA 4X, UL approved enclosure. An output of 4 - 20 mA, 0 - 20 mA, or -8 to + 12 mA, selectable as scale or loop powered to provide versatility to interface with related equipment, must be standard equipment. Indicator comes with two low level relay contacts, standard. A knob to set tare weights is required. Indicator must be capable of 0.1 lb. or 0.1 kg up to 1000.0 lbs. or kg. Accuracy is 0.5% of full scale, or better.Model 1020™ 5 Digit Controller: Controller must be electronic with a two line, backlit alphanumeric digital display and housed in a NEMA 4X, UL approved enclosure. Available as single or dual channel and capable of displaying two channels simultaneously. A loop powered programmable output of 4 - 20 mA and four set points per channel must be standard equipment. Indicator must be capable of 0.1 lb. or 0.1 kg up to 5000 lbs. or 2268 kg. Accuracy is 0.25% of full scale, or better.