Skip to product information
1 of 1
International Crystal Laboratories →

50ml Reference Standard Oil - NIST/USFDA/ASTM Certified

50ml Reference Standard Oil - NIST/USFDA/ASTM Certified

SKU:HYD-d42b06

Certified 50ml Reference Standard Oil for precise hydrocarbon analysis with NIST/USFDA/ASTM certification.

Regular price $321.00
Regular price Sale price $321.00
Sale

Initiate Order

50ml Reference Standard Oil - NIST/USFDA/ASTM Certified

50ml Reference Standard Oil - NIST/USFDA/ASTM Certified

$321.00

Quantity: 1

Claim Your Seller Account

50ml Reference Standard Oil - NIST/USFDA/ASTM Certified

50ml Reference Standard Oil - NIST/USFDA/ASTM Certified

$321.00

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The 50ml bottle of Reference Standard Oil is essential for creating dilute reference standards for EPA methods 413.2/418.1. With NIST/USFDA/ASTM photometric certification, this oil is specifically designed for use with the IR Spectrophotometer Total Hydrocarbon Analyzer. The model 2930 offers precise analysis of both volatile and nonvolatile oily samples to detect total hydrocarbons dissolved in non-absorbing solvents. Its fixed 3.42 micron wavelength, 30 cm-1 bandwidth, and rapid analysis capability make it ideal for institutional and government buyers looking for accurate hydrocarbon testing solutions.

Product Specifications

Additional Information 0
Water and hydrocarbons absorb in the near IR at 3.4 to 3.5 microns (2930 cm-1). By dissolving the oil content of a sample into fluorochlorocarbon (freon), which is nonabsorbing at 3.4 to 3.5 microns, and following the extraction procedure established in EPA methods 413.2 and 418.1, a working curve is prepared using blank solvent (freon) and known standards. Samples are then compared to the calibration curve in direct ppm readings shown on the instrument. Repeatability is ±1% on identical samples.The Model 2930 can also be used with hexane based EPA method 1664, which is an analysis technique that does not require the use of freon as a solvent. A special cell is an optional accessory for this freon-free technique.Features And Specifications Fixed 3.42 micron wavelength and 30 cm-1 bandwidth allows quick 10 second analysis without unnecessary scanning. Response time is a maximum of 40 seconds in damping 2 mode. Furthermore, the operating range permits the use of stable coated quartz optics that are not subject to degradation over time. Digital readout in %T, absorbance or concentration. Ranges: 0-100% T; 0-2 absorbance units; and 0-1 and 0-0.1 concentration. Built in scale expansion. Direct ppm readout. Recorder output is provided for optional recorder. Built in curve linearizer. Higher concentrations easily calibrated. Small footprint requires minimal benchspace. Portable. Weight: 20 pounds. Dimensions: 14” W x 11” D x 10” H. PbSe Peltier cooled detector provides signal to noise ratio of > 2500 to 1, instrument stability (drift) < 0.01 absorbance units per hour and photometric accuracy of ±1%. Instrument is simple to master and use, requires no maintenance, purging or special atmospheres and is warranted for a full year. Source is enclosed to avoid open source hazards. Electrical: 115/230v, 50-60 Hz, 80 watts.
Specifications List Price