Skip to product information
1 of 2
Thermal Care, Inc. →

Accuchiller KSE Series 120 Ton (t) Cooling Capacity Air Cooled Packaged Outdoor Chiller

Accuchiller KSE Series 120 Ton (t) Cooling Capacity Air Cooled Packaged Outdoor Chiller

SKU:ACC-ee03f4

N/A

Regular price $49.99
Regular price Sale price $49.99
Sale

Initiate Order

Accuchiller KSE Series 120 Ton (t) Cooling Capacity Air Cooled Packaged Outdoor Chiller

Accuchiller KSE Series 120 Ton (t) Cooling Capacity Air Cooled Packaged Outdoor Chiller

$49.99

Quantity: 1

Claim Your Seller Account

Accuchiller KSE Series 120 Ton (t) Cooling Capacity Air Cooled Packaged Outdoor Chiller

Accuchiller KSE Series 120 Ton (t) Cooling Capacity Air Cooled Packaged Outdoor Chiller

$49.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
KSE Series industrial outdoor air-cooled chillers feature a compact, all-in-one package designed to minimize installation cost, maximize usable space and lower electric bills. Designed for harsh outdoor environments KSE Series chillers require no options to operate within the standard -20 ºF to 125 ºF ambient environment conditions. Standard process fluid temperatures of 20 ºF to 80 ºF are ideal for industrial applications. The modular design allows up to 12 refrigeration circuits to be combined into a single system for up to 720 tons of cooling capacity.

Product Specifications

Additional Information
Wide operating conditionsAmbient Environment: -20 ºF to 125 ºFProcess Fluid Circuit: 20 ºF to 80 ºFIntegral air-cooled rugged microchannel condenser for class-leading efficiencyInnovative PLC Control System with a large high-resolution color touch-screen operator interface and an extensive list of operational information including remote monitoringDirect drive scroll compressors for low maintenance and energy efficiencyCompressor staging for capacity control with optional hot gas bypass for even greater unloading capabilitiesCompressor anti-cycle and start-up timerLead/lag compressor staging to alternate primary compressorBrazed plate evaporators maximize performance and increase resistance to costly freeze-up failuresStandard variable-speed drive fans reduce energy usage and provide optimum part-load performance for industry-leading IPLV, all while reducing noise levels for sound-sensitive environments C-UL 508A listed and labeled control panelIn-line evaporator strainers assure full evaporator performanceSingle point connection for electric hook-up at control cabinetElectronic expansion valvesLiquid line solenoid valves to extend compressor lifeRefrigerant sight glassesLiquid line filter driers with removable coresHigh and low refrigerant pressure switchesAlarm horn with silence button3-phase power monitoring and safety protectionEnvironmentally balanced 410a refrigerantChillers are available with or without integrated pumping packages, including high and low pressure pumping with dedicated stand-by and built-in pressurized and non-pressured tanks.KSE Series chillers come standard with Dynamic Lift technology to continuously calculate the lowest allowable refrigerant pressure for any combination of operating conditions for maximize chiller energy savings and stable process fluid temperatures of ±1 ºF.
Available Options
High and low pressure pumping with dedicated stand-by pump for quick and easy installationRotary non-fused disconnect switchHot-gas bypass minimum load capacity controlExpert field start-up provided by qualified service personnelCONNEX 4.0 for system-wide control5-year compressor parts warranty
Dimensions And Weights Chiller With High Pressure Pump With Dedi
6875 lb
Dimensions And Weight Chiller Only Operating Weight
6229 lb
Dimensions And Weight Chiller Only Shipping Weight
5954 lb
Dimensions Height
79 in
Dimensions Length
173 in
Dimensions Width
88 in
Flow Pressure And Weights Chiller With High Pressure Pump Nomina
288 gpm
Flow Pressure And Weights Chiller With High Pressure Pump Operat
6552 lb
Flow Pressure And Weights Chiller With High Pressure Pump Proces
25 hp
Flow Pressure And Weights Chiller With High Pressure Pump Shippi
6277 lb
Flow Pressure And Weights Chiller With Standard Pressure Pump No
288 gpm
Flow Pressure And Weights Chiller With Standard Pressure Pump Op
6498 lb
Flow Pressure And Weights Chiller With Standard Pressure Pump Pr
15 hp
Flow Pressure And Weights Chiller With Standard Pressure Pump Sh
6223 lb
Flow Pressure And Weights Chiller With Standard Pressure Pump Wi
6492 lb
Programmable Logic Control Plc System
PLC controls, monitors, and maintains stable and reliable operation of the chiller.
Specifications Compressor Quantity
4
Specifications Cooling Capacity
120 ton
Specifications Note For Cooling Capacity
Cooling tons based on 12,000 BTU/Hr/ton with 50 ºF leaving coolant and 95 ºF ambient air, R-410A refrigerant.
Specifications Process Inlet And Outlet Flange High Flow
6 in
Specifications Process Inlet And Outlet Flange Standard
4 in
Specifications Series
KSE
Specifications Set Point Temperature Range
20 to 80 ºF