AcuPro Infrared Gas Analyzers
AcuPro Infrared Gas Analyzers
SKU:ACU-2fc16d
Monitor flammable gases with precision using AcuPro Infrared Gas Analyzers. Designed for accuracy, reliability, and compliance with industry standards.
Regular price
$2,899.99
Regular price
Sale price
$2,899.99
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.
The AcuPro Infrared Gas Analyzers are designed for precise lower flammable limit (LFL/LEL) monitoring in clean, low temperature settings. With robust features like a heated optical cell, multiple relay functions, and a Modbus Protocol for digital output, these analyzers provide accurate gas concentration measurements. The NDIR detector ensures stability and accuracy, while the failsafe operation guarantees continuous monitoring reliability. Ideal for institutional and government procurement due to its explosion-proof design and compliance with industry standards.
Product Specifications
Assembly Design Assembly Design
The AcuPro® is an industrial strength analyzer with a complete sampling system, heated optical cell, and integrated controller for continuous measurement of flammable, and some combustible vapors, from 0% to 100% of the Lower Flammable Limit (%LFL, or LEL). It is suitable for monitoring a single solvent in a wide variety of processes. And it may be used for mixtures of solvents with a reduced level of accuracy in processes where the normal solvent concentrations are below 25%LFL.
Assembly Dimensions Depth
8.5 in
Assembly Dimensions Height
16 in
Assembly Dimensions Width
12.1 in
Failsafe Operation Failsafe Operation
A fault relay de-energizes whenever any of the following occur: controller electrical failure; loss of system power; loss of IR source and loss of flow.
Note Note
As a result of our commitment to product improvement, specifications are subject to change without notice.
Outputs Outputs
The system includes six relays: single-pole, double throw relays for Warning, Danger, Fault; and single-pole, single-throw relays for Horn, Calibration-in-Progress and Service Needed. Other standard outputs include a 4-20mA analog output and an RS-485 serial port with Modbus protocol. Digital remote access and control is available.
Performance Performance
The response time is less than 4 seconds. The analyzer exhibits a very stable zero: less than one percent drift in thirty days. Calibration accuracy has less than five percent error per year. AcuPro® is immune to poisoning and does not require oxygen for operation.
Power Requirement Alternating Current Ac Voltage
120 V
Power Requirement Alternating Current Ac Voltage Tolerance
-15 % | +10 %
Power Requirement Frequency
50 Hz | 60 Hz
Power Requirement Maximum Power
400 W
Power Requirement Optional Alternating Current Ac Voltage
230 V
Sampling System Sampling System
An integrated sampling system extracts a sample from the process using a built-in aspirator that develops suction from compressed air. This method is simple, has no moving parts and requires very little maintenance.Infrared energy is passed through the sample, and the amount of infrared energy that is absorbed determines the concentration of solvent vapors. Multiple infrared detectors at select wavelengths help convert concentration data into %LFL flammability readings with greater accuracy for a wider range of solvent types.Autocalibration solenoids, which allow remote activation of calibration tests, are standard.
Sensor Design Sensor Design
The analyzer's non-dispersive infrared detector (NDIR) has a unique heated, multiple-wavelength, mirrorless design. Heating to 60ºC prevents errors from process temperature changes, prevents condensation of water vapor, and maintains accuracy for solvents with Flash Points up to 60ºC. A multiple wavelength detector reduces variation in reading for different solvent types. And the mirrorless design simplifies maintenance by reducing the effects of contamination on the optical cell.
Specifications Air Consumption
21 L/min | 42 scfh
Specifications Alarm Function
Adjustable Alarm Ranges
Specifications Analog Output Current
4 to 20 mA
Specifications Digital Output
Modbus Protocol | RS-485 Serial
Specifications Enclosure Rating
National Electrical Manufacturers Association (NEMA) 12, Indoor | National Electrical Manufacturers Association (NEMA) 4X (Optional)
Specifications Hazardous Area Rating
Class I, Division 2, Groups A, B, C, D | Purged to Class I Division 1 (Optional)
Specifications Lower Flammable Limit Lfl Calibration
0 to 100 %
Specifications Maximum Analog Output Impedance Includes Line Len
275 Ω
Specifications Operating Temperature Limits
-20 to 60 ºC | -4 to 140 ºF
Specifications Oxygen O2 In Sample
0 to 21 %
Specifications Regulated Clean And Dry Compressed Air
20 psig
Specifications Relative Humidity Range
0 to 100 %
Specifications Relays
Three (3) Single Pole Double Throw (SPDT) 60 Watt Contacts | Three (3) Single Pole Single Throw (SPST) 60 Watt Contacts
Specifications Relay Functions
Six relays for: Warning; Danger; Fault; Horn; Calibration-in-Progress and Service Needed
Specifications Repeatability
Within 1 % of measurement range
Specifications Response Time
< 4 sec
Specifications Sample Train Material
Brass | Hard-Coat Aluminum | Stainless Steel (Optional)
Specifications Sensor Cell Material
Hard-Coat Aluminum
Specifications Sensor Cell Rating
Explosion Proof, Class I, Division 1
Specifications Sensor Heated Operating Temperature
0 to 60 ºC | 0 to 140 ºF
Specifications Single Solvent Accuracy
± 3% of full scale reading or 10% of applied gas whichever is greater
Specifications Solvents Measured
Acetone | Ethanol | Ethyl Acetate | Heptane | Hexane | Isopropyl Acetate | Isopropyl Alcohol | Methyl Ethyl Ketone (MEK) | n-Propanol | n-Propyl Acetate | Toluene | Xylene
Specifications Span Stability Per Year
5 %
Specifications Zero Stability In 30 Days
1 %