Experience exceptional data acquisition with our Advanced Strain & Bridge Data Acquisition System. This turnkey solution features 16 or 32 channels with 10kS/s sample rate and 16-bit digitizer, ensuring precise measurements. With bridge completion, remote sense, shunt calibration, and low-pass filters, this system provides accurate results. The included PI660 Turnkey Software allows for easy setup, display, and real-time data acquisition, making it ideal for laboratory applications and research. Custom configurations are available to meet specific institutional requirements.

Product Specifications
Amplifier Bandwidth
5 kHz for gains <1,000 and 1 kHz for gains 1,000 and higher.
Amplifier Common Mode
80 dB plus gain in dB up to 110 dB, DC to 60 Hz for ±10 Volts.
Amplifier Gain
Programmable from 1 to 5,000 in 1, 2, 3, 5 steps with ±0.05% accuracy.
Amplifier Gain Stability
±0.01%, ±0.004%/ºC.
Amplifier Linearity Amplifier
±0.01% for gains < 1,000, ±0.02% for gains 1,000 and higher.
Amplifier Noise 10 Hz
0.1 µV rms RTI, 0.5 mV rms RTO.
Amplifier Noise 1 Khz
1.0 µV rms RTI, 0.5 mV rms RTO
Amplifier Recovery
120 µS to ±0.1% for 10X overload to ±10 V.
Amplifier Slew Rate
3.2 V/µS
Amplifier Source Current
±10 nA, ±1 nA/ºC.
Amplifier Zero Amplifier
Automatic to ±1 µV RTI, ±0.5 mV RTO.
Amplifier Zero Stability
±5 µV RTI, ±1 mV RTO, ±1 µV/ºC RTI, ±0.2 mV/ºC RTO. Short term: ±2 µV RTI, ±0.4 mV RTO for 8 hours.
Calibration Shunt
Two step Bipolar shunt, 0.5024 mV/V and 0.245 mV/V for 350 Ohm bridge, ±0.1%. For a 120 Ohm bridge, steps are 0.17235 mV/V and 0.08402 mV/V, ±0.1%.
Calibration Voltage Substitution
Alternate input for external calibration source. Programmable attenuator with steps of 1, 0.1 and 0.01, ±0.02% accuracy. Output of the attenuator is provided for verification.
Calibration Zero Calibration
Amplifier input disconnected and shorted.
Connections Calibration
15-Pin Type D mounted on rear panel. Mating connector supplied.
Connections Control
15-Pin Type D mounted on rear panel. Mating connector supplied.
Connections Synchronization
Category 5, enclosure to enclosure. 2-meter cable supplied.
Connections Usb
2-meter cable supplied.
Control Data Processor Cdp And Operators Workstation Pccowu Opti
USB 2.0 ports for up to eight 6000U enclosures. Additional 6000U enclosures accommodated by adding USB expansion cards.
Data Format Data Word
16 or 32-bits, 2's complement binary.
Data Format Sample Rates
Multiple sample rates consisting of the highest sample rate divided by binary numbers. Highest sample rate is programmable with 1 uS resolution.
Data Format Scan Table
Maximum format length is 65,536 samples.
Data Interface Clock Stability
100 ppm over temperature range.
Data Interface Latency
Processor and scan table dependent, typically less than 5 milliseconds.
Data Interface Output Rate
Processor dependent, typically over 5 million 16-bit samples/second.
Digitizer Continuity
Monotonic to 15 bits.
Excitationtransducer Power Current
50 mA limited to 70 mA.
Excitationtransducer Power Monitor
Calibration mode measures excitation voltage with ±0.05% accuracy.
Excitationtransducer Power Regulation
±0.01% for ±10% line and no-load to full-load using remote sensing.
Excitationtransducer Power Stability
±0.01%, ±0.005 %/ºC
Excitationtransducer Power Transducer Power
±12 or ±15 Volts (24 V optional) jumper selectable per channel. Transducer power available on separate pins from voltage excitation. Current is 50 mA per channel, limited to 200 mA maximum per card.
Excitationtransducer Power Voltage Excitation
Programmable per channel from 0-12 Volts in 1 Volt ±0.1% steps, or adjustable with 3.3 mV resolution.
Excitationtransducer Power Voltage Excitation Noise
200 µV peak-to-peak
Mechanical Depth
18 in
Mechanical Height
5 in
Mechanical Power Mechanical
115 or 230 VAC, 110%, 47 to 63 Hz, 400 Watts.
Mechanical Width
19 in
Overview Analog Bandwidth
1 kHz
Overview Excitationtransducer Power
+/-12V | +/-15V | Voltage