Skip to product information
1 of 5
AMETEK MOCON →

BASELINE® MNME Hydrocarbon Analyzer

BASELINE® MNME Hydrocarbon Analyzer

SKU:PRO-5581e7

Cutting-edge MNME Hydrocarbon Analyzer for precise methane & non-methane gas measurement in environmental & industrial settings.

Regular price $12,999.00
Regular price Sale price $12,999.00
Sale

Initiate Order

BASELINE® MNME Hydrocarbon Analyzer

BASELINE® MNME Hydrocarbon Analyzer

$12,999.00

Quantity: 1

Claim Your Seller Account

BASELINE® MNME Hydrocarbon Analyzer

BASELINE® MNME Hydrocarbon Analyzer

$12,999.00

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The BASELINE® MNME Hydrocarbon Analyzer from AMETEK® | MOCON® is a cutting-edge instrument designed for precise measurement of methane and non-methane gases. Equipped with a Flame Ionization Detector (FID) with Oxidizer, this analyzer offers user-defined ranges for accurate results. With features like multilevel concentration alarms, graphical touch display, and LAN/Ethernet output, it ensures effortless operation and reliable performance. Ideal for environmental and semiconductor applications, this analyzer meets modern interface standards and compliance requirements.

Product Specifications

Accessories Accessories
Preventative Maintenance KitIncludes all necessary partsGas GeneratorsHydrogen generatorZero air generators Service & Support OptionsStart-up and training, one day onsite
Electrical Specifications Alternating Current Ac Voltage
100 to 240 V
Electrical Specifications Current
1 A
Electrical Specifications Frequency
50 Hz | 60 Hz
Features Features
High Performance Effortless OperationIndustry-approved gas measurementReliable performance meets modern interfaceThe BASELINE® Series of Continuous Hydrocarbon Analyzers (CHAs) from AMETEK MOCON® are instruments designed for continuous ambient or process hydrocarbon gas measurement in environmental or industrial settings. All instruments in the series are powered by our high-quality Flame Ionization Detection (FID) sensor, which enables fast, accurate measurement and low detection limits with minimal interference.The CHA Series combines reliable, industry-proven technology with a modern interface and straightforward troubleshooting, allowing you to focus on the results.Operation designed for humansHigh-quality data isn't enough if the instrument is difficult to use. The CHA Series features an intuitive, streamlined interface. Instruments include a range of capabilities to help simplify your process, including easily read results, real-time graphing, the ability to review historical data without pausing instrument operation, and dual display output. The CHA Series also features networking capabilities for easier connectivity, data sharing within a network, and remote diagnostics.Fast and Accurate - FIDOur proprietary FlowGuard electronic control regulates the delivery of fuel, air and a small portion of the sample gas to the FID. During combustion, gases are ionized, measured and reported as a concentration. This method provides fast gas measurement with some of the highest accuracy levels on the market.Intuitive InterfaceModern GUI interfaceDual display capabilitySimple DiagnosticsOn-board data storageReal-time graphingSynchronous operation and data reviewHigh PerformanceLow detection levelsFast measurementAutomatic calibration
Physical Specifications Depth
16.25 in | 41.28 cm
Physical Specifications Height
5.25 in | 13.02 cm
Physical Specifications Weight
< 20 lb | 9.07 kg
Physical Specifications Width
19 in | 48.26 cm
Specifications Industry Focus
Environmental | Semiconductors
Technical Specifications Accuracy Repeatability
+1% full-scale
Technical Specifications Alarms
Multilevel concentration and fault alarms, audible and visual
Technical Specifications Calibration
Programmable automatic or manual calibration
Technical Specifications Configuration
Benchtop or 19" (48.3 cm) Rack-Mount, 3U
Technical Specifications Detector
Flame Ionization Detector (FID) with Oxidizer
Technical Specifications Display Orientation
Diagonal
Technical Specifications Display Size
7 in | 17.8 cm
Technical Specifications Display Type
Graphical Touch Display
Technical Specifications Drift Span
+1% full-scale, 24 hours
Technical Specifications Drift Zero
+0.01% full-scale, 24 hours
Technical Specifications Non Condensing Operating Humidity
0 to 95 %
Technical Specifications Operating Temperature
32 to 104 ºF | 0 to 40 ºC
Technical Specifications Output
LAN/Ethernet, RS-485Optional outputsAnalog, programmable 0-20 mA/4-20 mA isolated output; Relays, 5 programmable From A relays rated to 3 A at 230 VACIf (a) is installed, 8 additional analog outputs and up to 16 additional relays can be added
Technical Specifications Ranges Ch4
User definable based upon calibration:Low - 0.03 ppm to 50 ppmMedium - 0.06 ppm to 500 ppmHigh - 0.15 ppm to 5000 ppm
Technical Specifications Response Time
T90 < 30 seconds
Technical Specifications Sampling
Internal single or multi-point, (pump optional)
Technical Specifications Support Gas Requirement
UHP Hydrogen (H2) 35 cc/minZero air - 175 cc/minSpan gas - methane/propane is typical
Unique Needs Unique Needs
Whether collecting ambient air quality data or monitoring emissions to stay below required levels, environmental applications require highly accurate results and easy access to data for compliance and reporting.