The Carrier Model 06E Reciprocating Semi-Hermetic Refrigerant Duty Compressor is a powerhouse designed for demanding refrigeration applications. With a CFM of 99 and 6 cylinders, this compressor delivers optimal performance with 35 horsepower and a max wattage of 47600. Its high efficiency design, catalog number CAR218, ensures reliable operation. To maintain system cleanliness and integrity, proper evacuation and dehydration procedures are recommended, along with the use of essential accessories like crankcase heaters, terminal plates, unloaders, and gaskets.

Product Specifications

Accessories Accessories
CAR-1018-E, Accessories | CAR-1032-H, Crankcase Heaters | CAR-1037-T, Terminal Plates & Parts | CAR-1040-U, Unloaders | CAR-1041-U, Unloaders | CAR-1042-GK-M, Gaskets | CAR-1043-U, Unloaders | CAR-1046-H, Crankcase Heaters | CAR-1047-H, Crankcase Heaters | CAR-1069-GK-M, Gaskets | CAR-1072-GK-M, Gaskets | CAR-1073-GK-M, Gaskets | CAR-1074-GK-M, Gaskets | CAR-1081-T, Terminal Plates & Parts | CAR-1082-GK-F, Gaskets | CAR-1089-T, Terminal Plates & Parts | CAR-1114-VP, Valve Plates & Parts | CAR-1115-VP, Valve Plates & Parts | CAR-1120-GK-F, Gaskets | CAR-1123-CP, Cast Parts | CAR-1124-CP, Cast Parts | CAR-1126-CP, Cast Parts | CAR-1127-CP, Cast Parts | CAR-1131-GK-M, Gaskets | CAR-1132-GK-M, Gaskets | CAR-1200-A, Accessories | CAR-1290-MK, Mounting Kits
Evacuation Procedure 0
System Cleanliness System cleanliness is one of the most important factors that affect system and compressor reliability. System contamination can cause both mechanical and electrical failures. There are several sources ofsystem contamination. Some of these are: Copper oxides from system refrigerant piping brazing. Refrigerant piping chips and burrs and brazing flux. Processing residue and metal chips from evaporators and condensers. Metal chips and wire brush strands from processing of other system components. Contamination in refrigeration tubing which is left uncapped during assembly. Moisture and air. In addition, field erected systems are subject to all the dirt and system contamination of the typical jobsite. It is recommended that a suction line filter be installed in the system to prevent contaminants form entering the compressor ; Evacuation and Dehydration For the refrigeration system to work property, it must be free of air and moisture. The process by which air and moisture are removed is known as evacuation and dehydration. Moisture and air are harmful to the system because they increase the condensing temperature, raise the discharge gas temperature, cause oil breakdown and the formation of acids. Acids are corrosive to the components in the refrigeration system, including the piping, refrigerant specialties, and the which can cause mechanical failure of the compressor.The recommended method for evacuation and dehydration is to evacuate the system from both the gigh and low sides to 800 microns or less. To establish that the unit is leakfree and moisture-free, a standing vacuum test is recommended. The maximum allowable rise over a 15 minute period is 200 microns. If the Hse exceeds this, either there is still moisture in teh system or a leak is present in the system See Chart 1.CAUTIONNEVER USE OXYGEN OR ACETYLENE IN PLACE OF REFRIGERANT AND DRY NITROGEN FOR LEAK TESTING. A VIOLENT EXPLOSION MAY RESULT, CAUSING PERSONAL INJURY OR DEATH.ALWAYS USE A PRESSURE REGULATOR WHEN USING NITROGEN TO PRESSURE TEST. FAILURE TO DO SO WILL RESULT IN EXTREMELY HIGH PRESSURE WHICH COULD EXCEED THE BURST PRESSURE OF TEH COMPRESSOR OR OTHER SYSTEM COMPONENTS AND RESULT IN PERSONAL INJURY OR DEATH.FOR SHELF STORAGE EVAC. TO 250 MICRONS
Specifications Catalog Number
CAR218
Specifications Cfm
99
Specifications Horsepower
35
Specifications Max Watts
47600
Specifications No Of Cylinders
6
Specifications Oil Charge Oz
304