Carrier Model 06E Refrigerant Duty Compressor
Carrier Model 06E Refrigerant Duty Compressor
SKU:COM-9e5ef3
High-performance Carrier 06E Refrigerant Compressor for low-temperature applications. 99 CFM, 6 cylinders, 35HP.
Regular price
          
            $2,499.99
          
      
          Regular price
          
            
              
                
              
            
          Sale price
        
          $2,499.99
        
      
      
        Unit price
        
          
          
           per 
          
          
        
      
    Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.
                The Carrier Model 06E Reciprocating Semi-Hermetic Refrigerant Duty Compressor is a high-performance solution designed for low-temperature refrigeration applications. With a CFM of 99, 35 Horsepower, and a maximum of 40000 Watts, this compressor features 6 cylinders for efficient cooling. It comes with a substantial oil charge of 304 oz, ensuring smooth operation and longevity. Additionally, a range of accessories such as crankcase heaters, gaskets, and terminal plates are available to enhance functionality and flexibility.
              
Product Specifications
                  Accessories Accessories 
                
                CAR-1018-E, Accessories | CAR-1032-H, Crankcase Heaters | CAR-1037-T, Terminal Plates & Parts | CAR-1040-U, Unloaders | CAR-1041-U, Unloaders | CAR-1042-GK-M, Gaskets | CAR-1043-U, Unloaders | CAR-1046-H, Crankcase Heaters | CAR-1047-H, Crankcase Heaters | CAR-1069-GK-M, Gaskets | CAR-1072-GK-M, Gaskets | CAR-1073-GK-M, Gaskets | CAR-1074-GK-M, Gaskets | CAR-1081-T, Terminal Plates & Parts | CAR-1082-GK-F, Gaskets | CAR-1089-T, Terminal Plates & Parts | CAR-1114-VP, Valve Plates & Parts | CAR-1115-VP, Valve Plates & Parts | CAR-1120-GK-F, Gaskets | CAR-1123-CP, Cast Parts | CAR-1124-CP, Cast Parts | CAR-1126-CP, Cast Parts | CAR-1127-CP, Cast Parts | CAR-1131-GK-M, Gaskets | CAR-1132-GK-M, Gaskets | CAR-1200-A, Accessories | CAR-1290-MK, Mounting Kits
              
                  Evacuation Procedure 0 
                
                System Cleanliness       System cleanliness is one of the most important factors that affect system and compressor reliability. System contamination can cause both mechanical and electrical failures. There are several sources ofsystem contamination. Some of these are:  Copper oxides from system refrigerant piping brazing. Refrigerant piping chips and burrs and brazing flux. Processing residue and metal chips from evaporators and condensers. Metal chips and wire brush strands from processing of other system components. Contamination in refrigeration tubing which is left uncapped during assembly. Moisture and air. In addition, field erected systems are subject to all the dirt and system contamination of the typical jobsite. It is recommended that a suction line filter be installed in the system to prevent contaminants form entering the compressor ;              Evacuation and Dehydration       For the refrigeration system to work property, it must be free of air and moisture. The process by which air and moisture are removed is known as evacuation and dehydration. Moisture and air are harmful to the system because they increase the condensing temperature, raise the discharge gas temperature, cause oil breakdown and the formation of acids. Acids are corrosive to the components in the refrigeration system, including the piping, refrigerant specialties, and the which can cause mechanical failure of the compressor.The recommended method for evacuation and dehydration is to evacuate the system from both the gigh and low sides to 800 microns or less. To establish that the unit is leakfree and moisture-free, a standing vacuum test is recommended. The maximum allowable rise over a 15 minute period is 200 microns. If the Hse exceeds this, either there is still moisture in teh system or a leak is present in the system See Chart 1.CAUTIONNEVER USE OXYGEN OR ACETYLENE IN PLACE OF REFRIGERANT AND DRY NITROGEN FOR LEAK TESTING. A VIOLENT EXPLOSION MAY RESULT, CAUSING PERSONAL INJURY OR DEATH.ALWAYS USE A PRESSURE REGULATOR WHEN USING NITROGEN TO PRESSURE TEST. FAILURE TO DO SO WILL RESULT IN EXTREMELY HIGH PRESSURE WHICH COULD EXCEED THE BURST PRESSURE OF TEH COMPRESSOR OR OTHER SYSTEM COMPONENTS AND RESULT IN PERSONAL INJURY OR DEATH.FOR SHELF STORAGE EVAC. TO 250 MICRONS
              
                  Specifications Catalog Number 
                
                CAR184
              
                  Specifications Cfm 
                
                99
              
                  Specifications Horsepower 
                
                35
              
                  Specifications Max Watts 
                
                40000
              
                  Specifications No Of Cylinders 
                
                6
              
                  Specifications Oil Charge Oz 
                
                304
              
                  Specifications Type 
                
                Low Temperature Refrigeration 06E