Skip to product information
1 of 1
Mod-Tronic Instruments Limited →

Cecomp DPG2000BBL-D4 Digital Pressure & Vacuum Gauge

Cecomp DPG2000BBL-D4 Digital Pressure & Vacuum Gauge

SKU:CEC-0405de

The Cecomp DPG2000BBL-D4: Accurate, rugged, and versatile digital gauge for pressure and vacuum applications. Ideal for government procurement.

Regular price $249.99
Regular price Sale price $249.99
Sale

Initiate Order

Cecomp DPG2000BBL-D4 Digital Pressure & Vacuum Gauge

Cecomp DPG2000BBL-D4 Digital Pressure & Vacuum Gauge

$249.99

Quantity: 1

Claim Your Seller Account

Cecomp DPG2000BBL-D4 Digital Pressure & Vacuum Gauge

Cecomp DPG2000BBL-D4 Digital Pressure & Vacuum Gauge

$249.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Cecomp DPG2000BBL-D4 is a versatile battery-powered digital gauge with exceptional accuracy of ±0.25%. It covers pressure ranges from 0-3 psi to 5000 psi, including vacuum and absolute ranges. Featuring a rugged design, 316 stainless steel wetted parts, and NEMA 4X models, this gauge is shock-resistant and reliable in demanding environments. With features like fast display response, bi-color alarm LEDs, and easy zero & span calibration, it offers unparalleled functionality. Approved by Factory Mutual for hazardous locations, it complies with Class I Div 1, making it ideal for government and institutional procurement needs.

Product Specifications

Specifications Accuracy
Includes linearity, hysteresis, repeatability ±0.25% of full scale ±1 least significant digit HA option: ±0.1% of full scale ±1 least significant digit. See range table below for availabilityIncludes linearity, hysteresis, repeatability ±0.25% of full scale ±1 least significant digit HA option: ±0.1% of full scale ±1 least significant digit.
Specifications Additional Information
Absolute reference availableSelectable engineering units available: psi, inHg, oz/in2, inH2O, ftH2O, mmH2O, cmH2O, mmHg, Torr, g/cm2, mbar, bar, kPa, MPa, atm, kg/cm2 depending on rangeD4 = 4 digit display, microprocessor basedM0 = Min/Max memory offBL = backlit display
Specifications Agency Approval
Factory Mutual Approved Intrinsically Safe for Hazardous Locations USA & Canada Class I, Division 1, Groups A, B, C, D T3C Ta = –40 to 82°C; T4 Ta = –40 to 66°C, CL I Zone 0 AEx/Ex ia IIC T3 Ta = –40 to 82°C; T4 Ta = –40 to 66°C
Specifications Approvals
Class I | Div 1 | Groups A, B, C, D, Zone 0 | Intrinsically Safe
Specifications Auto Shutoff
Default 5 minutes, user selectable 1 minute to 8 hrs or on/off
Specifications Backlight Battery Life
150 to 1000 h
Specifications Backlit Display
Yes
Specifications Batteries
Two 1.5 V AAA (Panasonic LR03) alkaline cells B: Approx. 1000 hours BL: Approx. 150 to 1000 hours depending on backlight usage Low battery symbol on display
Specifications Battery Life
1000 h
Specifications Burst Pressure
4 X sensor pressure rating, or 10,000 psi, whichever is less
Specifications Calibration
Non-interactive zero, span, and linearity, ±10% of range Internal setup/calibration buttons, internal lockout switch.
Specifications Calibration Setup
Internal
Specifications Connection Sensor Material
1/4" NPT male fitting, 316L stainless steel All wetted parts are 316L stainless steel
Specifications Controls Function
Front button turns gauge on or off, zeros gauge reference gauges, and cycles through min/max functions (if enabled) Internal buttons for engineering unit selection, auto shutoff time, min/max setup, calibration Internal lockout switch to disable setup and calibration. BL: Keypress activates backlighting for 1 min. if low light detected
Specifications Display
3 readings per second nominal display update rate 4 digit LCD, 0.5" H and 5 character 0.25" H alphanumeric BL: Red LED backlight. Front button activates backlighting for 1 minute if ambient light is insufficient
Specifications Environmental
Compensated: 32 to 158°F (0 to 70°C) | Operating: –40 to 185°F (–40 to 85°C) | Storage: –40 to 203°F (–40 to 95°C)
Specifications Factory Mutual Fm Approved
Yes
Specifications Features
4 digit display | Optional ±0.1% accuracy in most ranges | All metal housing | Optional top gauge port | Includes 2 AAA batteries | Configurable to capture minimum and/or maximum readings | Tamper-resistant internal buttons for setup | Calibration with pass code protection
Specifications Housing Materials Circuit Board Protection
Epoxy powder coated aluminum case, rear cover, and bezel. Front and rear rubber gaskets, polycarbonate label. Includes stainless steel stiffener plate to reinforce sensor area. Conformal coating on circuit boards for moisture resistance.
Specifications Material
316 Stainless Steel
Specifications Memory Options
Std: Min/max enabled M0: Min/max turned off in user setup Min/max can be user configured to be individually enabled or disabled, saved or cleared at power off
Specifications Minimummaximum Zero
Yes
Specifications Options
±0.1% AccuracyBacklit Display (Most Models) National Electrical Manufacturers Association (NEMA) 4X Housing (Most Models) Most Engineering Units Available National Institute of Standards and Technology (NIST) Traceability Panel or Surface Mounting (Most Models) Protective Rubber Boot Hi/Lo, Hi/Hi, Lo/Lo, Normal or Reverse Alarms
Specifications Overpressure Burst Vacuum
All others: 2 X pressure range | Ranges using 3000 psig sensor: 5000 psig | Ranges using 5000 psig sensor: 7500 psig
Specifications Power
Battery (2 x AA)
Specifications Ranges
Vacuum to 5000 psi
Specifications Ranges And Resolution
Consult factory for special engineering units. Units may be changed to any listed under the same sensor range. Resolution is fixed and limited to available display digits
Specifications Test Gauge Accuracy
0.25 %
Specifications Warranty
1 y
Specifications Weight
Approximately 9 ounces, shipping weight 1 pound.