For continuous carbon dioxide (CO2) monitoring of controlled atmosphere (C/A) food storage rooms, breweries, wineries, food packaging plants, or any area where CO2 is handled.The Nova 523 Series Carbon Dioxide alarm monitors are designed for the continuous detection of CO2 in ambient air or in air drawn from a confined space or C/A room. A built-in sample pump draws in a sample through a filter and flowmeter and then on to the CO2 detector. This model uses a solid state infrared CO2 detector which continuously detects and displays the CO2 on a front panel digital meter. A 0-1V or 4-20mA linear output signal is available for input to a recorder or similar device.Model 523P has a built-in pump sensor.
Product Specifications
Applications 0
For continuous carbon dioxide (CO2) monitoring of controlled atmosphere (C/A) food storage rooms, breweries, wineries, food packaging plants, or any area where CO2 is handled.
Calibration 0
Ambient air for O2 and to zero all other gasesAnalyzed calibration gas with representative concentrations for span of all other gases
Features 0
Standard infrared detector Fast warm-up, approx. 1 minuteBright digital readout - no reading interpretation errors.Easy use and calibrateEasy to maintain modular layout4-20mA output signal for recordingNEMA 12 fiberglass enclosure is standard
Options 0
'Fail Safe' alarms availableStrobe lightNEMA 4 or 4X enclosuresCold weather package for operation to -5°F (-20°C)
Specifications Accuracy Repeatability
±2% of full scale
Specifications Ambient Temperature Range
32 to 120°F (0 to 40°C), may be operated at lower temperature with auxiliary heater
Specifications Drift
Less than 2% of full scale per week, whichever is greater
Specifications Linearity
±2% of full scale
Specifications Method Of Detection
PPM CO2 by infrared detector
Specifications Output Options
0-1 VDC | 4-20 mA
Specifications Power
115 VAC, 60 Hz | 220 VAC, 50 Hz
Specifications Ranges Available
0-5,000 PPM standard
Specifications Resolution
10 PPM
Specifications Response Time T 90
Less than 15 seconds to 90% step change
Specifications Size Weight
14" H x 12" W x 8" D (35.6 x 30.5 x 20.3 cm) @ 18 lbs. (8.2 kg)
Unique Applications 0