Continuous Multigas Ambient Air Analyzer - 501 Series
Continuous Multigas Ambient Air Analyzer - 501 Series
SKU:BYP-111d42
N/A
Regular price
$49.99
Regular price
Sale price
$49.99
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.


The 501 Series four gas versions offer a choice of O2, CO2, CO, NO, & NO2. Single gas verions are also available with H2S, SO2, Cl2, & NH3. An O2 sensor may be added to the single gas versions to produce a toxic gas plus oxygen deficiency monitor.A built-in pump draws in the sample for analysis. A ¼" plastic tube may be attached to the analyzer to sample a different area, such as a room or confined space. Standard system comes with NEMA4 enclosure, built-in sampling pump, flow meter, and filter. Warm-up time is approximately four minutes after initial power-up. The operating ambient humidity range for this series of analyzers is 0-90% RH non-condensing. Alarm option - alarms may be provided for all gases. An optional audible 'Sonalert' will sound if any reading goes into alarm and display indication on front panel shows which gas is in alarm. Acknowledgement function will silence the audible 'Sonalert'.
Product Specifications
Applications 0
For simultaneous monitoring of up to four gases in ambient air including O2, CO2, NO, NO2, CO, temperature, and % RH. Single gas versions are also available for H2S, SO2, Cl2, & NH3.
Calibration 0
On clean air or nitrogen for Zero On analyzed calibration gas for Span
Features 0
All gas detectors contained in durable NEMA 4 wall-mounted enclosure Separate sensor for each gas Bright digital readout for gas readings Built-in sampling pump Easy to maintain modular layout
Options 0
Non-isolated 4-20mA recorder outputs Isolated analog 4-20mA outputs available Alarms with local indication and relay contacts with audible alarm & acknowledge Red strobe light mounted on top of analyzer Low Flow alarm with local indication and relay contact
Specifications Accuracy Repeatability
±2% of full scale
Specifications Alarms
Optional - One low or one high O2 alarm and one high alarm for all other gases. Separate SPDT relay contacts for each gas with 5A rating. Display indication. Common 'Sonalert' audible alarm with ACKN function.
Specifications Ambient Temperature Range
40° to 105°F (4° to 40°C) ºC
Specifications Drift
< 2% per month
Specifications Gases Measured
0) NH3 - 0-20 PPM | 1) O2 - 0-25.0% | 2) CO - 0-200 PPM | 3) CO2 - 0-5000 PPM | 4) H2S - 0-20 PPM | 5) SO2 - 0-50 PPM | 6) NO - 0-100 PPM | 7) NO2 - 0-20 PPM | 8) Cl2 - 0-20 PPM
Specifications Linearity
Better than ±2% of full scale
Specifications Method Of Detection
O2, CO, SO2, NO, NO2, H2, CL2, NH3, and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor
Specifications Output Options
4-20 mA into 500 ohms non-isolated standard | Isolated 4-20 mA
Specifications Power
115 VAC, 60 Hz for recharging | 220 VAC, 50 Hz
Specifications Ranges Available
0-100 PPM NO | 0-20 PPM Cl2 | 0-20 PPM H2S | 0-20 PPM NH3 | 0-20 PPM NO2 | 0-200 PPM CO | 0-200 PPM H2 | 0-25.0% O2 | 0-50 PPM SO2 | 0-5000 PPM CO2 | -40°C to +40°C / 0-100% RH
Specifications Resolution
0.1% on O2; 1 PPM on PPM gases; 1% RH; 0.1°C Temp.
Specifications Response Time T 90
Varies with individual sensor but generally under 2 minutes for full reading
Specifications Size Weight
NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D)