National Compressor Exchange, Inc. →

Copeland Reciprocating Compressors MD, 2D, 3D, 4D, 6D, 8D

Copeland Reciprocating Compressors MD, 2D, 3D, 4D, 6D, 8D

SKU:COM-af7d0f

High-performance Copeland Reciprocating Compressors for refrigeration & AC applications. Reliable & efficient with Texas Instruments motor protection sensors.

Regular price $1,899.99
Regular price Sale price $1,899.99
Sale

Initiate Order

Copeland Reciprocating Compressors MD, 2D, 3D, 4D, 6D, 8D

Copeland Reciprocating Compressors MD, 2D, 3D, 4D, 6D, 8D

$1,899.99

Quantity: 1

Claim Your Seller Account

Copeland Reciprocating Compressors MD, 2D, 3D, 4D, 6D, 8D

Copeland Reciprocating Compressors MD, 2D, 3D, 4D, 6D, 8D

$1,899.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Copeland Models MD, 2D, 3D, 4D, 6D, 8D Reciprocating Compressors are designed for refrigeration and air conditioning applications. With specifications including a Bore In of 2 11/16, 4 cylinders, Refrigerant-Cooled model, and a nominal HP of 25, these compressors ensure reliable performance. The motor protection sensors by Texas Instruments enhance operational safety. Accessories like pumps, mounting kits, and crankcase heaters are available for added convenience. This product meets Federal procurement standards and is compliant with industry-specific certifications, ensuring quality and reliability for institutional buyers.

Product Specifications

Accessories Accessories
CPE-1006-P, Pumps | CPE-1017-MK, Mounting Kits | CPE-1019-H, Crankcase Heaters | CPE-1020-H, Crankcase Heaters | CPE-1021-H, Crankcase Heaters | CPE-1022-H, Crankcase Heaters | CPE-1033-P, Pumps | CPE-1034-E, Accessories | CPE-1054-U, Unloaders | CPE-1055-U, Unloaders | CPE-1056-E, Accessories | CPE-1085-GK-F, Gaskets | CPE-1086-GK-F, Gaskets | CPE-1087-T, Terminal Plates & Parts | CPE-1088-T, Terminal Plates & Parts | CPE-1090-GK-F, Gaskets | CPE-1108-VP, Valve Plates & Parts | CPE-1116-VP, Valve Plates & Parts | CPE-1117-VP, Valve Plates & Parts | CPE-1118-VP, Valve Plates & Parts | CPE-1119-VP, Valve Plates & Parts | CPE-1125-CP, Cast Parts | CPE-1137-T, Terminal Plates & Parts | CPE-1209-GK-F, Gaskets | CPE-1210-GK-F, Gaskets | NCE-1002-E, Accessories | NCE-1003-E, Accessories | NCE-1004-E, Accessories | NCE-1007-E or CPE-1007-E, Accessories | NCE-1010-E, Accessories
Evacuation Procedure 0
System Cleanliness System cleanliness is one of the most important factors that affect system and compressor reliability. System contamination can cause both mechanical and electrical failures. There are several sources ofsystem contamination. Some of these are: Copper oxides from system refrigerant piping brazing. Refrigerant piping chips and burrs and brazing flux. Processing residue and metal chips from evaporators and condensers. Metal chips and wire brush strands from processing of other system components. Contamination in refrigeration tubing which is left uncapped during assembly. Moisture and air. In addition, field erected systems are subject to all the dirt and system contamination of the typical jobsite. It is recommended that a suction line filter be installed in the system to prevent contaminants form entering the compressor ; Evacuation and Dehydration For the refrigeration system to work property, it must be free of air and moisture. The process by which air and moisture are removed is known as evacuation and dehydration. Moisture and air are harmful to the system because they increase the condensing temperature, raise the discharge gas temperature, cause oil breakdown and the formation of acids. Acids are corrosive to the components in the refrigeration system, including the piping, refrigerant specialties, and the which can cause mechanical failure of the compressor.The recommended method for evacuation and dehydration is to evacuate the system from both the gigh and low sides to 800 microns or less. To establish that the unit is leakfree and moisture-free, a standing vacuum test is recommended. The maximum allowable rise over a 15 minute period is 200 microns. If the Hse exceeds this, either there is still moisture in teh system or a leak is present in the system See Chart 1.CAUTIONNEVER USE OXYGEN OR ACETYLENE IN PLACE OF REFRIGERANT AND DRY NITROGEN FOR LEAK TESTING. A VIOLENT EXPLOSION MAY RESULT, CAUSING PERSONAL INJURY OR DEATH.ALWAYS USE A PRESSURE REGULATOR WHEN USING NITROGEN TO PRESSURE TEST. FAILURE TO DO SO WILL RESULT IN EXTREMELY HIGH PRESSURE WHICH COULD EXCEED THE BURST PRESSURE OF TEH COMPRESSOR OR OTHER SYSTEM COMPONENTS AND RESULT IN PERSONAL INJURY OR DEATH.FOR SHELF STORAGE EVAC. TO 250 MICRONS
Motor Protection Motor Protection Sensors
Copeland has phased in a new source for motor protection modules and sensors that are used on all sensor-protected motors on hermetic and semi-hermetic reciprocating compressors. These motor protection devices have been supplied by Texas Instruments-Modules (40AAXXXX/ 41AA1600E), and sensors (3BA, 10BA).|| The new Kriwan modules and sensors are UL recognized and are identical in performance, fit and functionality to those currently supplied by Texas Instruments. Kriwan and Texas Instruments modules and sensors are completely interchangeable. There are no wiring changes required, and no customer testing is necessary. Please note the difference in cold resistance between Texas Instruments and Kriwan Sensors. This product resistance difference does not affect motor protection functionality.|| Texas Instrument | 3BA095-07 | 10BA095-1002A1 | Resistance 500 to 2600 OHMS ||Kriwan |01D-117-S31|01D-117-S31|Resistance 30 to 120 OHMS|||||Sensor Resistance (25 degree C, (77 degree F)|Or at ambient temperature||NOTE: Do not make a mistake; Due to the lower resistance on the Kriwan sensor, it matches the Robert Shaw readings but is not compatible. Kriwan is only compatible with Texas Instrument modules and Kriwan modules.
Specifications Bore In
2 11/16
Specifications Catalog Number
CPE-982
Specifications Cfh 60 Hz
3020
Specifications Model
Refrigerant-Cooled
Specifications Net Weight Lbs
425
Specifications Nominal Hp
25
Specifications No Of Cylinders
4
Specifications Oil Charge Oz
130 (120)
Specifications Ship Weight Lbs
445
Specifications Stroke In
2-3/16
Specifications Type
Refrigeration and Air Conditioning Motor-Compressors