National Compressor Exchange, Inc. →

Copeland Reciprocating Compressors MD,2D,3D,4D,6D,8D

Copeland Reciprocating Compressors MD,2D,3D,4D,6D,8D

SKU:COM-895f01

High-efficiency Copeland Reciprocating Compressors for industrial applications. Capacity control model, 20 HP, and robust design.

Regular price $2,899.99
Regular price Sale price $2,899.99
Sale

Initiate Order

Copeland Reciprocating Compressors MD,2D,3D,4D,6D,8D

Copeland Reciprocating Compressors MD,2D,3D,4D,6D,8D

$2,899.99

Quantity: 1

Claim Your Seller Account

Copeland Reciprocating Compressors MD,2D,3D,4D,6D,8D

Copeland Reciprocating Compressors MD,2D,3D,4D,6D,8D

$2,899.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Copeland Models MD, 2D, 3D, 4D, 6D, 8D Reciprocating Compressors are designed for high efficiency and reliability in industrial applications. With a bore size of 2 11/16 inches, 6 cylinders, and a nominal HP of 20, these compressors offer robust performance. Featuring a capacity control model, they ensure precise operation and energy savings. Weighing 480 lbs with a net weight of 500 lbs, these compressors are equipped for heavy-duty usage. Included accessories such as pumps, mounting kits, crankcase heaters, unloaders, and valve plates enhance functionality for seamless integration into various systems.

Product Specifications

Accessories Accessories
CPE-1006-P, Pumps | CPE-1017-MK, Mounting Kits | CPE-1019-H, Crankcase Heaters | CPE-1020-H, Crankcase Heaters | CPE-1021-H, Crankcase Heaters | CPE-1022-H, Crankcase Heaters | CPE-1033-P, Pumps | CPE-1034-E, Accessories | CPE-1054-U, Unloaders | CPE-1055-U, Unloaders | CPE-1056-E, Accessories | CPE-1085-GK-F, Gaskets | CPE-1086-GK-F, Gaskets | CPE-1087-T, Terminal Plates & Parts | CPE-1088-T, Terminal Plates & Parts | CPE-1090-GK-F, Gaskets | CPE-1108-VP, Valve Plates & Parts | CPE-1116-VP, Valve Plates & Parts | CPE-1117-VP, Valve Plates & Parts | CPE-1118-VP, Valve Plates & Parts | CPE-1119-VP, Valve Plates & Parts | CPE-1125-CP, Cast Parts | CPE-1137-T, Terminal Plates & Parts | CPE-1209-GK-F, Gaskets | CPE-1210-GK-F, Gaskets | NCE-1002-E, Accessories | NCE-1003-E, Accessories | NCE-1004-E, Accessories | NCE-1007-E or CPE-1007-E, Accessories | NCE-1010-E, Accessories
Evacuation Procedure 0
System Cleanliness System cleanliness is one of the most important factors that affect system and compressor reliability. System contamination can cause both mechanical and electrical failures. There are several sources ofsystem contamination. Some of these are: Copper oxides from system refrigerant piping brazing. Refrigerant piping chips and burrs and brazing flux. Processing residue and metal chips from evaporators and condensers. Metal chips and wire brush strands from processing of other system components. Contamination in refrigeration tubing which is left uncapped during assembly. Moisture and air. In addition, field erected systems are subject to all the dirt and system contamination of the typical jobsite. It is recommended that a suction line filter be installed in the system to prevent contaminants form entering the compressor ; Evacuation and Dehydration For the refrigeration system to work property, it must be free of air and moisture. The process by which air and moisture are removed is known as evacuation and dehydration. Moisture and air are harmful to the system because they increase the condensing temperature, raise the discharge gas temperature, cause oil breakdown and the formation of acids. Acids are corrosive to the components in the refrigeration system, including the piping, refrigerant specialties, and the which can cause mechanical failure of the compressor.The recommended method for evacuation and dehydration is to evacuate the system from both the gigh and low sides to 800 microns or less. To establish that the unit is leakfree and moisture-free, a standing vacuum test is recommended. The maximum allowable rise over a 15 minute period is 200 microns. If the Hse exceeds this, either there is still moisture in teh system or a leak is present in the system See Chart 1.CAUTIONNEVER USE OXYGEN OR ACETYLENE IN PLACE OF REFRIGERANT AND DRY NITROGEN FOR LEAK TESTING. A VIOLENT EXPLOSION MAY RESULT, CAUSING PERSONAL INJURY OR DEATH.ALWAYS USE A PRESSURE REGULATOR WHEN USING NITROGEN TO PRESSURE TEST. FAILURE TO DO SO WILL RESULT IN EXTREMELY HIGH PRESSURE WHICH COULD EXCEED THE BURST PRESSURE OF TEH COMPRESSOR OR OTHER SYSTEM COMPONENTS AND RESULT IN PERSONAL INJURY OR DEATH.FOR SHELF STORAGE EVAC. TO 250 MICRONS
Specifications Bore In
2 11/16
Specifications Catalog Number
CPE-940
Specifications Cfh 60 Hz
4530
Specifications Model
Capacity Control
Specifications Net Weight Lbs
480
Specifications Nominal Hp
20
Specifications No Of Cylinders
6
Specifications Oil Charge Oz
135 (120)
Specifications Ship Weight Lbs
500
Specifications Stroke In
2-3/16