                The CP Disposable Media Filter Capsules with Nano-Spun NSPD Membrane offer cost-effective filtration solutions for small flow applications. Designed for efficiency, these capsules come in various grades including food/beverage, electronic, and pharmaceutical, meeting FDA requirements and maintaining high filtration standards. Constructed with FDA-accepted materials, they ensure integrity and quality, making them ideal for liquids and gas applications. With a Certificate of Quality Assurance provided for specific grades, these capsules reduce filtration costs and eliminate the need for expensive metallic housings.
              
Product Specifications
                  Construction Materials Filtration Media 
                
                Polypropylene 99%
              
                  Construction Materials Filtration Media Support Material 
                
                Polypropylene
              
                  Construction Materials Grade 
                
                Food & Beverage
              
                  Construction Materials Housing 
                
                Polypropylene
              
                  Construction Materials Note 
                
                All materials of construction are FDA accepted. Final assemblies have been validated to pass USP class 6 Toxicology extractable tests, oxidizable substances for plastics, endotoxin level and other quality tests.
              
                  Construction Materials Sealing Method 
                
                Heat - Fused
              
                  Construction Materials Support Components Material 
                
                Polypropylene
              
                  Filtration Media 0 
                
                Nano-Spun - NSNSPD Media filter cartridges have been designed to hold large amounts of contaminant and still provide 99% retention efficiencies at the rated pore size. Made of 100% polypropylene these cartridges can be used wherever a high contamination load application requires retention efficiencies above nominal. NS is an excellent choice where protection of more expensive membrane filters is required or a high efficiency depth filter is all that is required.
              
                  Flow Rate 0 
                
                See the Flow Rate table in more image which represents typical water flow at a one psi (69 mbar) pressure differential across a single 2 inch capsule 1.0 ft2 (5.08 cm) of media with 1/2 inch FNPT ports. The test fluid is water at ambient temperature. Higher pressure drops is acceptable, but as flows increase the pressure drop of the housing becomes more apparent.
              
                  Maximum Operating Parameters Forward Differential Pressure At 20 
                
                50 psi | 3.4 bar
              
                  Maximum Operating Parameters Gases Operational Pressure At 20c 
                
                60 psi | 4.1 bar
              
                  Maximum Operating Parameters Liquid Operational Pressure At 20c 
                
                80 psi | 5.5 bar
              
                  Maximum Operating Parameters Operating Temperature At 30 Psi 14 
                
                110 ºF | 43 ºC
              
                  Maximum Operating Parameters Recommended Change Out Pressure 
                
                20 psid | 2.4 bar
              
                  Maximum Operating Parameters Reverse Differential Pressure At 20 
                
                40 psi | 2.7 bar
              
                  Pore Size Removal Ratings 
                
                0.03 to 100 µ
              
                  Quality Standards 0 
                
                Our goal is to ensure our customers the greatest possible value for their filtration dollar. We achieve both low cost manufacture and high quality by employing state of the art manufacturing equipment. This computer controlled equipment is highly automated, reducing hand operations that compromise quality. Each operation including assembly, testing, cleaning, drying and packaging is done in appropriately rated clean rooms. Critical Process Filtration manages an ISO 9000 facility that produces validated products to rigorous standards. Manufacturing is controlled using sophisticated MRP software that is networked to work stations in manufacturing centers and inspection points. During the manufacturing and inspection processes, data is collected âreal timeâ from machinery and measuring instruments. This allows variable and attribute data to be quickly and easily analyzed to facilitate constant improvements in both quality and cost.
              
                  Sanitization Sterilization Autoclave 
                
                250ºF (121ºC), 30 min, multiple cycles
              
                  Sanitization Sterilization Chemical Sanitization 
                
                Industry standard concentrations of hydrogen peroxide, paracetic acid, sodium hypochlorite and other selected chemicals. Sanitization protocols designed to extend the useful life of CP capsules are available from Critical Process Filtration, Inc.®.
              
                  Sanitization Sterilization Filtered Hot Water 
                
                194 ºF | 90 ºC
              
                  Sanitization Sterilization Inlet Outlet Options 
                
                1/2" Female NPT | 1/2" Male NPT | 1/4 Male NPT | 1/4" Female NPT | 3/8" Female NPT | Hose Barb | Sanitary
              
                  Sanitization Sterilization Pre Sterilized 
                
                Not Sterilized | Pre- Sterilized
              
                  Sanitization Sterilization Vent Drain 
                
                Standard with Luer- Lok¨ ports and caps
              
                  Specifications Capsule Length 
                
                2 in | 5 in | 10 in | 23 in | 30 in
              
                  Specifications Filter Mediamembrane 
                
                Nano Spun NSPD
              
                  Specifications Grade Definition 
                
                Food and beverage grade capsules have been designed to comply with all FDA requirements for the food industry. Each module is flushed with 17+ megohm-cm water to ensure that no manufacturing debris remains downstream to contaminate your product. This washing also ensures that all extractables which may effect the taste of the product are removed. F grade capsules are designed to give maximum throughput and handle cleaning and sanitization protocols well. Each cartridge module is individually tested for integrity.
              
                  Specifications Micron Rating 
                
                2.0 µ
              
                  Total Performance 0 
                
                Critical Process Filtration, Inc.® is a vertically integrated supplier of filtration products and services to industries in which filtration is considered to be a critical part of the manufacturing process. We manufacture a complete line of products to help you achieve all your filtration requirements from a single source.
              
                  Usp Biosafety 0 
                
                The materials used to construct the membrane capsule filters are non-toxic and meet the requirements for the MEM Elution Cytotoxicity Test and USP24 Plastic Class V1 121ºC Test.