The Critical Process Disposable Media Filter Capsules are meticulously engineered for cost-effective filtration. These capsules, designed for small flow applications, offer a wide range of pleated and depth media options to cater to various industry needs. With a focus on quality assurance and traceability, each capsule is designed to maximize filter media utilization while reducing the demand for expensive metallic housings. Ideal for liquid and gas applications, these capsules are FDA accepted and undergo rigorous testing to meet stringent filtration standards.
Product Specifications
Construction Materials Filtration Media
Nylon
Construction Materials Filtration Media Support Material
Polypropylene
Construction Materials Grade
General
Construction Materials Housing
Polypropylene
Construction Materials Note
All materials of construction are FDA accepted. Final assemblies have been validated to pass USP class 6 Toxicology extractable tests, oxidizable substances for plastics, endotoxin level and other quality tests.
Construction Materials Sealing Method
Heat - Fused
Construction Materials Support Components Material
Polypropylene
Filtration Media 0
Nylon Membrane - NMNM Capsules are hydrophilic Nylon membrane, able to remove particles below the rated pore size of the membrane. These capsules exhibit superior retention, used across the beverage, electronic and pharmaceutical industries. Applications include high purity water, esters, solvents, cosmetics, alcohols, ketones, glycols and many others. PNM grade Nylon capsules are designed to be used as sterilizing grade capsules for the pharmaceutical industry. Nylon capsules see broad service in sterile fill applications in SVPs and as bio burden management filters in LVPs. Media and service liquid filtration are other common applications for this capsule. Nylon is particularly suited for the filtration of solvents because of itâs broad compatibility and low level of extractables. 100% integrity tested.
Flow Rate 0
See the Flow Rate table in more image which represents typical water flow at a one psi (69 mbar) pressure differential across a single 2 inch capsule 1.0 ft2 (930 cm2) of media with 1/2" FNPT ports. The test fluid is water at ambient temperature. Higher pressure drops is acceptable, but as flows increase the pressure drop of the housing becomes more apparent.
Maximum Operating Parameters Forward Differential Pressure At 20
50 psi | 3.4 bar
Maximum Operating Parameters Gases Operational Pressure At 20c
60 psi | 4.1 bar
Maximum Operating Parameters Liquid Operational Pressure At 20c
80 psi | 5.5 bar
Maximum Operating Parameters Operating Temperature At 30 Psi 14
110 ºF | 43 ºC
Maximum Operating Parameters Recommended Change Out Pressure
20 psid | 2.4 bar
Maximum Operating Parameters Reverse Differential Pressure At 20
40 psi | 2.7 bar
Pore Size Removal Ratings
0.03 to 100 µ
Quality Standards 0
Our goal is to ensure our customers the greatest possible value for their filtration dollar. We achieve both low cost manufacture and high quality by employing state of the art manufacturing equipment. This computer controlled equipment is highly automated, reducing hand operations that compromise quality. Each operation including assembly, testing, cleaning, drying and packaging is done in appropriately rated clean rooms. Critical Process Filtration manages an ISO 9000 facility that produces validated products to rigorous standards. Manufacturing is controlled using sophisticated MRP software that is networked to work stations in manufacturing centers and inspection points. During the manufacturing and inspection processes, data is collected âreal timeâ from machinery and measuring instruments. This allows variable and attribute data to be quickly and easily analyzed to facilitate constant improvements in both quality and cost.
Sanitization Sterilization Autoclave
250ºF (121ºC), 30 min, multiple cycles
Sanitization Sterilization Chemical Sanitization
Industry standard concentrations of hydrogen peroxide, paracetic acid, sodium hypochlorite and other selected chemicals. Sanitization protocols designed to extend the useful life of CP capsules are available from Critical Process Filtration, Inc.®.
Sanitization Sterilization Filtered Hot Water
194 ºF | 90 ºC
Sanitization Sterilization Inlet Outlet Options
1/2" Female NPT | 1/2" Male NPT | 1/4 Male NPT | 1/4" Female NPT | 3/8" Female NPT | Hose Barb | Sanitary
Sanitization Sterilization Pre Sterilized
Not Sterilized | Pre- Sterilized
Sanitization Sterilization Vent Drain
Standard with Luer- Lok¨ ports and caps
Specifications Capsule Length
2 in | 5 in | 10 in | 23 in | 30 in
Specifications Filter Mediamembrane
Nylon Membrane
Specifications Grade Definition
Designed for general purpose use at an effective cost. Each module is rinsed with 17+ megohm-cm water to remove potential extraneous manufacturing debris. Each cartridge module is individually tested for integrity.
Specifications Micron Rating
100 µ
Total Performance 0
Critical Process Filtration, Inc.® is a vertically integrated supplier of filtration products and services to industries in which filtration is considered to be a critical part of the manufacturing process. We manufacture a complete line of products to help you achieve all your filtration requirements from a single source.
Usp Biosafety 0
The materials used to construct the membrane capsule filters are non-toxic and meet the requirements for the MEM Elution Cytotoxicity Test and USP24 Plastic Class V1 121ºC Test.
Validation 0
P - grade capsules are validated using modified HIMA protocols at a challenge level of 107 organisms per cm2 of filter media.F & E - grade capsules are validated using modified HIMA protocols at a challenge level of 106 organisms per cm2 of filter media.G - grade capsules are validated using modified HIMA protocols at a challenge level of 104 organisms per cm2 of filter media.(0.22 µm challenged with Brevundimonas diminuta) (0.45 µm challenged with Serratia marscecens) (0.65 µm challenged with Saccharomyces cerevisiae).