Dansensor MAP Mix Provectus Argon Gas Mixers
Dansensor MAP Mix Provectus Argon Gas Mixers
SKU:PRO-e1d5be
Revolutionary gas mixer with touchscreen control, data logging, and CE compliance. Perfect for precise gas mixtures.
Regular price
$4,499.99
Regular price
Sale price
$4,499.99
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.

The Dansensor MAP Mix Provectus Argon Gas Mixers revolutionize gas mixing with advanced accuracy and operation. Featuring intuitive touch screen control, data logging, and compatibility with various gas media, this mixer ensures precise gas mixtures. With compliance to European Conformity (CE) standards, this mixer is highly reliable, offering vital feedback on gas flow and consumption. Ideal for institutional and government buyers, it meets traceability requirements and integrates smoothly with gas analyzers for optimal efficiency.
Product Specifications
Additional Information Additional Information
Your only decision is whether you need to mix two or three gasses. All other specifications can be set the first time you start the gas mixer.Even though it is only slightly larger than a shoebox, the Dansensor® MAP Mix Provectus Argon still delivers an outstanding gas mixing capacity of up to 90 m3/hour (3200 SCHF). If you require even more, you can bridge up to three mixers and triple the capacity.
Benefits Benefits
Uses an intuitive touch screen for easy set-up and operationMeets traceability requirements by storing accurate information about current gas flow, consumption over time and gas mix Avoids operator errors with programing of up to 10 standard gas mixes Integrates fully with the Dansensor® MAP Check 3 gas analyzer for ultimate eff effectiveness
Features Features
Data logging of consumption, date, time and gas mix Very low pressure drop over the mixer, making it suitable for working with nitrogen and oxygen generators USB, Ethernet (LAN), RS232, Modbus TCP connections for data logging and control Mixes oxygen, nitrogen, carbon dioxide, air and argon (optional)
How Does It Work How Does It Work
After unpacking, use the intuitive touch screen to easily program the mixer according to the gasses connected and the desired gas mixture. The Dansensor® MAP Mix Provectus Argon can be programmed with up to 10 preset gas mixtures for easy change of gas mix by the operator.During operation the Dansensor® MAP Mix Provectus Argon ensures the correct gas mixture for the application and keeps the operator informed about inlet pressure, outlet pressure and gas flow. In case of any irregularities, the mixer alerts the operator.The Dansensor® MAP Mix Provectus Argon provides operators and quality personnel with vital information about actual gas consumption, inlet pressure, outlet pressure and gas mixture. Best of all, everything can be logged and transferred to a PC or an external data warehouse.
Note Note
Specifications subject to change without notice.
Specifications Autoranging Alternating Current Ac Voltage
103 to 132 V | 207 to 264 V
Specifications Bracket Assembly
Can be combined with MAP Check 3 and MAP Check Vacuum 3: 2 brackets, 8 screws.
Specifications Buffer Tank Kit
Tank 15 L, fittings
Specifications Compliances
European Conformity (CE)
Specifications Connections
2 x RS232C| LAN 10/100 Mbit (Modbus TCP)| USB| 24 VDC Logic for Start/Stop and Alarm
Specifications Depth
375 mm
Specifications Flow Measuring
Total and daily consumption.
Specifications Flow Range For Best Case Mix For 2 Gases At Ar 50
12 to 1000 L/min
Specifications Flow Range For Best Case Mix For 3 Gases At Ar 34
18 to 1470 L/min
Specifications Flow Range For Mix1 For 2 Gases At Ar 82
33 to 609 L/min
Specifications Flow Range For Mix1 For 2 Gases At Ar 90
60 to 555 L/min
Specifications Flow Range For Mix1 For 3 Gases At Ar 70
60 to714 L/min
Specifications Flow Range For Mix2 For 3 Gases At Ar 70
300 to 714 L/min
Specifications Flow Range For Worst Case Mix For 2 Gases At Ar 9
300 to 509 L/min
Specifications Flow Range For Worst Case Mix For 3 Gases At Ar 8
300 to 568 L/min
Specifications Frequency
47 to 63 Hz
Specifications Gas Flow Per Gas String At 021 To 176 Standard Cu
6 to 500 L/min
Specifications Gas Inlet Pressure
30 to 145 psi | 2 to 10 bar
Specifications Gas Media
Dry and clean O2, CO2, Ar, N2 or Air (0°C to +50°C / 32°F to +122°F gas temperature )
Specifications Height
192 mm
Specifications Maximum Output Gas Flow 2 Gas
1000 L/min | 2115 scfh
Specifications Maximum Output Gas Flow 3 Gas
1500 L/min | 3175 scfh
Specifications Mixer Accuracy
± 2% absolute in flow ranges above 50 L/min (105 SCFH) total output flow. Argon: ± 2% absolute at argon flow > 50 bar
Specifications Mixer Configurations
2-gas or 3-gas models available, with LCD display or as "Black-Box" without display
Specifications Mixer Setting Range
0.2 to 100 %
Specifications Note For Maximum Output Gas Flow
Depending on mixture setting
Specifications Operating Modes
Buffer or flow configuration, selectable in software and by installation
Specifications Pressure Drop
Example: 1 bar at 10 bar input pressure (14.5 psi at 145 psi input pressure)
Specifications Protection Kit
Ingress Protection (IP45) National Electrical Manufacturers Association (NEMA 3S)
Specifications Weight
12.0 to 14.0 kg
Specifications Width
230 mm