National Compressor Exchange, Inc. →

DB metic Dunham-Bush Compressor 15 HP DB688

DB metic Dunham-Bush Compressor 15 HP DB688

SKU:COM-fb136d

Powerful 15 HP DB metic Dunham-Bush Compressor with advanced evacuation procedures for optimal system cleanliness.

Regular price $2,999.99
Regular price Sale price $2,999.99
Sale

Initiate Order

DB metic Dunham-Bush Compressor 15 HP DB688

DB metic Dunham-Bush Compressor 15 HP DB688

$2,999.99

Quantity: 1

Claim Your Seller Account

DB metic Dunham-Bush Compressor 15 HP DB688

DB metic Dunham-Bush Compressor 15 HP DB688

$2,999.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The DB metic Dunham-Bush Compressor is a reliable and powerful 15 HP unit designed for optimal performance in various settings. Weighing 899 lb, this compressor is equipped with necessary specifications including a Catalog Number: DB688. Ensure system cleanliness and reliability with its advanced evacuation procedures that eliminate contaminants and moisture, ensuring long-term efficiency and durability.

Product Specifications

Evacuation Procedure 0
System Cleanliness System cleanliness is one of the most important factors that affect system and compressor reliability. System contamination can cause both mechanical and electrical failures. There are several sources ofsystem contamination. Some of these are: Copper oxides from system refrigerant piping brazing. Refrigerant piping chips and burrs and brazing flux. Processing residue and metal chips from evaporators and condensers. Metal chips and wire brush strands from processing of other system components. Contamination in refrigeration tubing which is left uncapped during assembly. Moisture and air. In addition, field erected systems are subject to all the dirt and system contamination of the typical jobsite. It is recommended that a suction line filter be installed in the system to prevent contaminants form entering the compressor ; Evacuation and Dehydration For the refrigeration system to work property, it must be free of air and moisture. The process by which air and moisture are removed is known as evacuation and dehydration. Moisture and air are harmful to the system because they increase the condensing temperature, raise the discharge gas temperature, cause oil breakdown and the formation of acids. Acids are corrosive to the components in the refrigeration system, including the piping, refrigerant specialties, and the which can cause mechanical failure of the compressor.The recommended method for evacuation and dehydration is to evacuate the system from both the gigh and low sides to 800 microns or less. To establish that the unit is leakfree and moisture-free, a standing vacuum test is recommended. The maximum allowable rise over a 15 minute period is 200 microns. If the Hse exceeds this, either there is still moisture in teh system or a leak is present in the system See Chart 1.CAUTIONNEVER USE OXYGEN OR ACETYLENE IN PLACE OF REFRIGERANT AND DRY NITROGEN FOR LEAK TESTING. A VIOLENT EXPLOSION MAY RESULT, CAUSING PERSONAL INJURY OR DEATH.ALWAYS USE A PRESSURE REGULATOR WHEN USING NITROGEN TO PRESSURE TEST. FAILURE TO DO SO WILL RESULT IN EXTREMELY HIGH PRESSURE WHICH COULD EXCEED THE BURST PRESSURE OF TEH COMPRESSOR OR OTHER SYSTEM COMPONENTS AND RESULT IN PERSONAL INJURY OR DEATH.FOR SHELF STORAGE EVAC. TO 250 MICRONS
Notes Note
1. All single phase compressors except 1/4, 1/3, supplied less relay, terminal box and terminal strip. 2. All three phase compressors supplied less terminal box and terminal strip. 3. When ordering specify voltage, phase, and number of terminals. Can be 3-5-6 or 8 including protection.
Specifications Catalog Number
DB688
Specifications Horsepower
15
Specifications Weight
899 lb