DF Series High Pressure Inline Industrial Filter (6090 PSI)
DF Series High Pressure Inline Industrial Filter (6090 PSI)
SKU:HYD-78e8ac
Discover the powerful DF Series High Pressure Inline Industrial Filter - ideal for 6090 psi applications with outstanding durability and reliability.
Regular price
          
            $549.99
          
      
          Regular price
          
            
              
                
              
            
          Sale price
        
          $549.99
        
      
      
        Unit price
        
          
          
           per 
          
          
        
      
    Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.

                The DF Series High Pressure Inline Industrial Filter is an essential component for hydraulic systems requiring filtration up to 6090 psi and a maximum flow capacity of 200 gpm. With a durable steel cap, Nitrile Rubber seals, and a bypass valve for optimal performance during cold starts, this filter ensures reliable operation in diverse industries like agriculture, automotive, construction, and more. Its non-welded housing design and O-ring seals enhance longevity while providing compatibility with various fluids. Meet stringent institutional procurement requirements with this high-quality, high-pressure filter from the renowned DF Series.
              
Product Specifications
                  Application 0 
                
                AgriculturalAutomotiveConstructionGearboxesIndustrialPulp & PaperOffshoreRailwaysCommercial MunicipalShipbuildingPower GenerationSteel / Heavy Industry
              
                  Dimensions Diameter D1 
                
                4.69 in | 119 mm
              
                  Dimensions Dimension B1 
                
                4.92 in | 125 mm
              
                  Dimensions Dimension B2 
                
                3.74 in | 95 mm
              
                  Dimensions Dimension B3 
                
                3.35 in | 85 mm
              
                  Dimensions Dimension B4 
                
                1.38 in | 35 mm
              
                  Dimensions Dimension D2 
                
                3.74 in | 95 mm
              
                  Dimensions Dimension D3 
                
                1-1/4 in.
              
                  Dimensions Dimension D4 
                
                3/8-24UNF- 2B
              
                  Dimensions Dimension H1 
                
                9.57 in | 243 mm
              
                  Dimensions Dimension H2 
                
                1.85 in | 47 mm
              
                  Dimensions Dimension H4 
                
                4.13 in | 105 mm
              
                  Dimensions Dimension T1 
                
                0.55 in | 14 mm
              
                  Features 0 
                
                Non-welded housing design reduces stress concentrations and prevents fatigue failure.Choice of NPT, BSPP, SAE straight thread O-ring boss, and SAE 4-bolt flange porting (sizes 60 - 1320) to allow easy installation with maximum flexibility.O-ring seals are used to provide positive, reliable sealing.Choice of O-ring materials (nitrile rubber, fluorocarbon elastomer, and ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids. Screw-in bowl or lid (on 2-pc. bowls) mounted below the filter head requires minimal clearance to remove the element for replacement and contaminated fluid cannot be washed downstream when element is serviced. HYDAC Differential Pressure Indicators have no external dynamic seal. This results in a high system reliability due to magnetic actuation, thus eliminating a potential leak point. A poppet-type bypass valve located in the filter head provides positive sealing during normal operation and fast opening during cold starts and flow surges. (Optional non-bypass available) For special finishes and coatings - consult HYDAC for minimum quantities, availability and pricing. Fatigue pressure ratings equal maximum allowable working pressure rating
              
                  Specifications Bun 
                
                High Pressure
              
                  Specifications Cap Material 
                
                Steel
              
                  Specifications Division 
                
                HYDRAULIC AND LUBE FILTERS
              
                  Specifications Filter Type 
                
                Inline mount 4 mounting holes
              
                  Specifications Indication Type 
                
                BM = Pop-up indicator (manual reset)
              
                  Specifications Model Code Description 
                
                DF ON 160TE20BM1.0/3B3
              
                  Specifications Port Configuration 
                
                NPT ports - NPT ported filters will be SAE with adaptors in each port
              
                  Specifications Port Connection 
                
                1 1/4 "
              
                  Specifications Product 
                
                FILTERS-HIGH PRESSURE (>3000PSI)
              
                  Specifications Product Group Family 
                
                FILTERS-HIGH PRESSURE (ò3000 PSI)
              
                  Specifications Seals 
                
                Nitrile Rubber (NBR)
              
                  Specifications Size 
                
                160
              
                  Specifications Type 
                
                High Pressure Filter
              
                  Specifications Type Number 
                
                1
              
                  Specifications Weight 
                
                10.34 kg | 22.8 lb
              
                  Technical Specifications Burst Housing Pressure Rating 
                
                1180 bar | 17110 psi
              
                  Technical Specifications Bypass Valve 
                
                B3
              
                  Technical Specifications Bypass Valve Cracking Pressure 
                
                3 bar | 43 psid
              
                  Technical Specifications Construction Material For Head 
                
                Ductile iron
              
                  Technical Specifications Element Collapse Pressure Rating 
                
                20 bar | 290 psi
              
                  Technical Specifications Element K Factors 
                
                0.225
              
                  Technical Specifications Fatigue Housing Pressure Rating At 1 Mi 
                
                420 bar | 6090 psi
              
                  Technical Specifications Filter Rating 
                
                20 µm
              
                  Technical Specifications Flow Capacity 
                
                42 gpm | 160 L/min
              
                  Technical Specifications Flow Direction 
                
                Inside - Outside
              
                  Technical Specifications Fluid Compatibility 
                
                Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.