Hexane Calibration Standards 50ml - 10, 50, 250ppm
Hexane Calibration Standards 50ml - 10, 50, 250ppm
SKU:HYD-be08c7
Hexane Calibration Standards for Oil-in-Water Analyzer - Ensuring precise hydrocarbon testing results
Regular price
$1,390.00
Regular price
Sale price
$1,390.00
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.

Enhance your hydrocarbon testing process with the Hexane Calibration Standards in 10, 50, and 250ppm concentrations specifically designed for use with the Oil-in-Water Analyzer. These standards ensure accurate readings with a fixed 3.42 micron wavelength, 30 cm-1 bandwidth, and direct ppm readout capability. The Model 2930 offers a quick 10-second analysis without unnecessary scanning, high repeatability of ±1%, and a stable coated quartz optics system. This portable and easy-to-use instrument provides reliable results, making it an essential tool for hydrocarbon analysis in both institutional and industrial settings.
Product Specifications
Additional Information 0
Water and hydrocarbons absorb in the near IR at 3.4 to 3.5 microns (2930 cm-1). By dissolving the oil content of a sample into fluorochlorocarbon (freon), which is nonabsorbing at 3.4 to 3.5 microns, and following the extraction procedure established in EPA methods 413.2 and 418.1, a working curve is prepared using blank solvent (freon) and known standards. Samples are then compared to the calibration curve in direct ppm readings shown on the instrument. Repeatability is ±1% on identical samples.The Model 2930 can also be used with hexane based EPA method 1664, which is an analysis technique that does not require the use of freon as a solvent. A special cell is an optional accessory for this freon-free technique.Features And Specifications Fixed 3.42 micron wavelength and 30 cm-1 bandwidth allows quick 10 second analysis without unnecessary scanning. Response time is a maximum of 40 seconds in damping 2 mode. Furthermore, the operating range permits the use of stable coated quartz optics that are not subject to degradation over time. Digital readout in %T, absorbance or concentration. Ranges: 0-100% T; 0-2 absorbance units; and 0-1 and 0-0.1 concentration. Built in scale expansion. Direct ppm readout. Recorder output is provided for optional recorder. Built in curve linearizer. Higher concentrations easily calibrated. Small footprint requires minimal benchspace. Portable. Weight: 20 pounds. Dimensions: 14â W x 11â D x 10â H. PbSe Peltier cooled detector provides signal to noise ratio of > 2500 to 1, instrument stability (drift) < 0.01 absorbance units per hour and photometric accuracy of ±1%. Instrument is simple to master and use, requires no maintenance, purging or special atmospheres and is warranted for a full year. Source is enclosed to avoid open source hazards. Electrical: 115/230v, 50-60 Hz, 80 watts.
Specifications List Price
1390 USD