Hexane Method Vessel Cell Holder for Total Hydrocarbon Analysis
Hexane Method Vessel Cell Holder for Total Hydrocarbon Analysis
SKU:HYD-d383fb
Enhance your hydrocarbon testing efficiency with this Holder for Hexane Method Vessel Cell designed for Total Hydrocarbon Analysis.
Regular price
$160.00
Regular price
Sale price
$160.00
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.

The Holder for Hexane Method Vessel Cell is a key accessory for the efficient and accurate analysis of total hydrocarbons in water samples using the IR Spectrophotometer Total Hydrocarbon Analyzer. This holder facilitates the use of hexane based EPA method 1664, eliminating the need for freon as a solvent and ensuring compliance with environmental regulations. With a fixed 3.42 micron wavelength and 30 cm-1 bandwidth, quick 10-second analysis without scanning is possible. The instrument offers precise readings in %T, absorbance, or concentration with a wide range of 0-100% T, 0-2 absorbance units, and direct ppm readouts. Compact, portable, and easy to operate, this holder enhances the capabilities of the analyzer for reliable hydrocarbon testing.
Product Specifications
Additional Information 0
Water and hydrocarbons absorb in the near IR at 3.4 to 3.5 microns (2930 cm-1). By dissolving the oil content of a sample into fluorochlorocarbon (freon), which is nonabsorbing at 3.4 to 3.5 microns, and following the extraction procedure established in EPA methods 413.2 and 418.1, a working curve is prepared using blank solvent (freon) and known standards. Samples are then compared to the calibration curve in direct ppm readings shown on the instrument. Repeatability is ±1% on identical samples.The Model 2930 can also be used with hexane based EPA method 1664, which is an analysis technique that does not require the use of freon as a solvent. A special cell is an optional accessory for this freon-free technique.Features And Specifications Fixed 3.42 micron wavelength and 30 cm-1 bandwidth allows quick 10 second analysis without unnecessary scanning. Response time is a maximum of 40 seconds in damping 2 mode. Furthermore, the operating range permits the use of stable coated quartz optics that are not subject to degradation over time. Digital readout in %T, absorbance or concentration. Ranges: 0-100% T; 0-2 absorbance units; and 0-1 and 0-0.1 concentration. Built in scale expansion. Direct ppm readout. Recorder output is provided for optional recorder. Built in curve linearizer. Higher concentrations easily calibrated. Small footprint requires minimal benchspace. Portable. Weight: 20 pounds. Dimensions: 14â W x 11â D x 10â H. PbSe Peltier cooled detector provides signal to noise ratio of > 2500 to 1, instrument stability (drift) < 0.01 absorbance units per hour and photometric accuracy of ±1%. Instrument is simple to master and use, requires no maintenance, purging or special atmospheres and is warranted for a full year. Source is enclosed to avoid open source hazards. Electrical: 115/230v, 50-60 Hz, 80 watts.
Specifications List Price
160 USD