The Hydraulic Inline Filter - DF Series is a high-pressure filter designed for industrial applications, with a maximum working pressure rating of 6090 psi. Its robust construction features a steel cap, ductile iron head, and steel bowl, ensuring durability and reliability in demanding environments. The filter's non-welded housing design reduces stress concentrations, preventing fatigue failure. It offers flexibility in installation with various port configurations and seals for compatibility with different fluids. The poppet-type bypass valve ensures positive sealing during normal operation and fast opening during cold starts. Suitable for diverse industries such as automotive, steel, power generation, and more.

Product Specifications
Application 0
AgriculturalAutomotiveConstructionGearboxesIndustrialPulp & PaperOffshoreRailwaysCommercial MunicipalShipbuildingPower GenerationSteel / Heavy Industry
Features 0
Non-welded housing design reduces stress concentrations and prevents fatigue failure.Choice of NPT, BSPP, SAE straight thread O-ring boss, and SAE 4-bolt flange porting (sizes 60 - 1320) to allow easy installation with maximum flexibility.O-ring seals are used to provide positive, reliable sealing. Choice of O-ring materials (nitrile rubber, fluorocarbon elastomer, and ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.Screw-in bowl or lid (on 2-pc. bowls) mounted below the filter head requires minimal clearance to remove the element for replacement and contaminated fluid cannot be washed downstream when element is serviced.HYDAC Differential Pressure Indicators have no external dynamic seal. This results in a high system reliability due to magnetic actuation, thus eliminating a potential leak point.A poppet-type bypass valve located in the filter head provides positive sealing during normal operation and fast opening during cold starts and flow surges. (Optional non-bypass available)For special finishes and coatings - consult HYDAC for minimum quantities, availability and pricing.Fatigue pressure ratings equal maximum allowable working pressure rating.
Specifications Bun
EA
Specifications Cap Material
Steel
Specifications Division
HYDRAULIC AND LUBE FILTERS
Specifications Filter Type
Inline Filter
Specifications Indication Type
A = No indicator, plugged port
Specifications Model Code Description
DF ON 500TF20A1.0/12B6
Specifications Modification Number
0
Specifications Port Configuration
SAE Straight Thread O-ring Boss Ports
Specifications Port Connection
1 1/2 in. Threaded
Specifications Product
FILTERS-HIGH PRESSURE (>3000PSI)
Specifications Product Group Family
FILTERS-HIGH PRESSURE (ò3000 PSI)
Specifications Seals
Nitrile Rubber (NBR)
Specifications Type
High Pressure Filter
Specifications Type Number
1
Technical Specifications Bypass Valve
B6
Technical Specifications Bypass Valve Cracking Pressure
6 bar | 87 psid
Technical Specifications Construction Material For Bowl
Steel
Technical Specifications Construction Material For Head
Ductile iron
Technical Specifications Fatigue Housing Pressure Rating At 1 Mi
420 bar | 6090 psi
Technical Specifications Filter Rating
20 µm
Technical Specifications Flow Direction
Inside - Outside
Technical Specifications Fluid Compatibility
Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Technical Specifications Maximum Allowable Housing Working Press
420 bar | 6090 psi
Technical Specifications Maximum Fluid Temperature
100 ºC | 212 ºF
Technical Specifications Minimum Fluid Temperature
-10 ºC | 14 ºF
Technical Specifications Mounting Method
4 Mounting Holes
Technical Specifications Note For Fluid Temperature Range
Consult HYDAC for applications operating below 14ºF (-10ºC)
Technical Specifications Tolerance For Cracking Pressure Optiona
10 %
Technical Specifications Tolerance For Cracking Pressure Standar
10 %