Skip to product information
1 of 2
Nova Analytical Systems →

Model 207K-KX, Portable Standard Range Dew Point Analyzer

Model 207K-KX, Portable Standard Range Dew Point Analyzer

SKU:BYI-408c19

N/A

Regular price $49.99
Regular price Sale price $49.99
Sale

Initiate Order

Model 207K-KX, Portable Standard Range Dew Point Analyzer

Model 207K-KX, Portable Standard Range Dew Point Analyzer

$49.99

Quantity: 1

Claim Your Seller Account

Model 207K-KX, Portable Standard Range Dew Point Analyzer

Model 207K-KX, Portable Standard Range Dew Point Analyzer

$49.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Nova 207 Series Portable Dew Point Analyzers have been designed primarily for accurate dew point measurement of exothermic and endothermic heat treating atmospheres. The dielectric polymer sensor provides stable and accurate dew point measurements and is not affected by most gas compositions. (some exceptions) A built-in sample pump draws in samples that are of insufficient pressure from the process. The sample flow is shown on a small rotameter with valve. The analyzer then reads the dew point continuously.Models: 207K - suitcase cabinet with display on inside; display visible when case is opened 207KX - suitcase cabinet with display on outside; display visible when case is closed

Product Specifications

Applications 0
For checking dew points of air, heat treat furnace gases, compressed air lines, and other applications with oils or contaminants present.
Calibration 0
Calibration is easily performed in the field using the optional calibration kit (part no. TGI50317SUB). Alternatively, the analyzer may be returned to Nova for a certified calibration
Features 0
Standard range of -40 to +104°F (-40 to +40°C) Dew Point Rugged design that is easy to operate Use on any non-corrosive gas Long-life dielectric polymer sensor May be calibrated in the field Bright digital readout Built in sample pump, filter and flow meter Suitcase style (K) enclosure is standard Sensor easily replaced if contaminated Factory calibrated to NIST traceable standards
Options 0
4-20mA recorder output Calibration kit Built-in printer (KX) display on outside of case
Specifications Accuracy Repeatability
±1°F (±1°C) Dew Point
Specifications Alarms
High or low dew point alarms with LED (optional)
Specifications Ambient Temperature Range
4° to 49°C ºC | 40° to 120°F ºF
Specifications Drift
Less than 1% of full scale range per month
Specifications Hazardous Area Rating Options
General Purpose, Non-Hazardous
Specifications Linearity
Better than 1°F (1°C) Dew Point
Specifications Method Of Detection
Dielectric polymer sensor that change capacitance with moisture variation
Specifications Output Options
4-20mA
Specifications Power
115 VAC 60 Hz for recharging | 220VAC 50Hz available
Specifications Ranges Available
-40°C to +40°C (or -40°F to +104°F) Dew Point
Specifications Resolution
1°F (1°C) Dew Point
Specifications Response Time T 90
Less than 30 seconds
Specifications Size Weight
K Suitcase Style - Approx. 14" L x 6" H x 11" D @ 12 lbs (36 x 15 x 27 cm @ 5.4 kg
Unique Applications 0
The 207 Series should not be used to measure dew points when trace amounts of sulfur trioxide (SO3), chlorine (Cl2), hydrogen chloride (HCl), or ammonia (NH3) are present. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.