Skip to product information
1 of 1
Nova Analytical Systems →

Model 410 D1 or D2, Oxygen Analyzer with cabinet purge systems for hazardous areas

Model 410 D1 or D2, Oxygen Analyzer with cabinet purge systems for hazardous areas

SKU:BYP-df1263

N/A

Regular price $49.99
Regular price Sale price $49.99
Sale

Initiate Order

Model 410 D1 or D2, Oxygen Analyzer with cabinet purge systems for hazardous areas

Model 410 D1 or D2, Oxygen Analyzer with cabinet purge systems for hazardous areas

$49.99

Quantity: 1

Claim Your Seller Account

Model 410 D1 or D2, Oxygen Analyzer with cabinet purge systems for hazardous areas

Model 410 D1 or D2, Oxygen Analyzer with cabinet purge systems for hazardous areas

$49.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Nova FLEXI-NOVA Series Platform has been designed for continuous gas measurements in applications and environments that are less intensive. Lab work, research, clean processes, pre-treated / pre-cleaned produced gases, and others, may benefit from the FLEXI-NOVA series. Depending on application, some light-duty sample conditioning features may be available. For clean process measurements, percent-level O2 gas. This sensor utilizes a paramagnetic measuring cell and powerful selenium cobalt magnet assembly to make use of the principle that oxygen is drawn into a magnetic field, thereby offering a method of detection that is very specific to oxygen. Sample dew point should be at least 5°C (9°F) below lowest sample temperature. All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Easy calibration using touch-screen controls. Serial Output Package allows connection & data-logging to personal computers via a choice of USB / RS-232 / RS-485.Cabinet: NEMA 4 cabinet with Hazardous Area Purge System; available for Class 1 Div1 & Div2 hazardous areas

Product Specifications

Applications 0
For continuous analysis of oxygen (O2) in process gas streams that contain gases that interfere with other methods of O2 measurement. For high accuracy or high purity applications.
Calibration 0
Nitrogen for zero Air or analyzed calibration gas for span
Features 0
Highest accuracy O2 analyzer, very stable Fast response (T90 - 4 to 5 seconds) and bright digital readout Linear over entire 0-100% range Microprocessor control Non-consumable O2 detector, no periodic replacement required Built in sample pump or pressure regulator, and 4 - 20 mA outputs To improve accuracy, detector can be mounted in temperature controlled heated box and compensated for changes in barometric pressure at the vent
Options 0
Hi/Low gas, low flow alarms available Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available Sample conditioning systems available for removal of moisture and dust Cabinet purge system available for use in hazardous areas Cabinet coolers can be fitted to most models High purity version available for 98-100% O2 (412HP)
Specifications Accuracy Repeatability
±0.5% of full scale or 0.05%, whichever is greater
Specifications Alarms
High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
Specifications Ambient Temperature Range
40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler
Specifications Analyzer Type
O2 Analyzer
Specifications Drift
±0.2% of full scale per month
Specifications Hazardous Area Rating Options
Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available
Specifications Linearity
±0.5% of full scale or 0.05%, whichever is greater
Specifications Method Of Detection
Magneto-dynamic paramagnetic O2 cell
Specifications Output Options
4-20 mA into 500 ohms non-isolated standard | Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
Specifications Power
115 VAC, 60 Hz | 220 VAC, 50 Hz
Specifications Ranges Available
With back-pressure control: 1.00, 2.00, 5.00, 25.00, 100.0 % O2 | Without back-pressure control: 1.0, 2.0, 5.0 % O2
Specifications Resolution
±1% of full scale
Specifications Response Time T 90
4 - 5 seconds at a sample flow of 1 LPM
Specifications Size Weight
Dimensions will vary depending on purge system and options required | NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D)
Unique Applications 0
All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.