Parker MAN Series Piston Style Actuators
Parker MAN Series Piston Style Actuators
SKU:VAL-7edaea
Control valves remotely with Parker MAN Series Piston Style Actuators - reliable, corrosion-resistant, and efficient for heavy-duty service.
Regular price
$499.99
Regular price
Sale price
$499.99
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.


Enhance your process control with Parker MAN Series Piston Style Actuators - an essential component for remote valve operation. Available in Fail Open or Fail Close options, these piston actuators ensure reliability, corrosion resistance, and efficient operation. Built to meet heavy duty outdoor service demands with a maximum working pressure of 100 psi, these actuators offer ease of maintenance, high cycle life, and compatibility with remote operation systems.
Product Specifications
Dimensions A
7.50 in
Dimensions Approx Air Usage
.08 scfm
Dimensions Area Of Piston
39.2 in²
Dimensions B
5.70 in
Dimensions Duty Rating
Heavy
Dimensions Max Allowable Working Pressure
100 psi
Dimensions Service
Outdoor
Dimensions Type
Fail Open
Specifications Features And Benefits
Fail Open or Fail Close with spring return or Dual Acting (air controls both directions) Piston actuator sizing incorporates maximum allowable air pressure of 100 psi Yoke design for separation of process and air controls Stem Position Indicator is standard Anodized Aluminum Housing (for corrosion and wear resistance) -20°F (-29°C) to 200°F (93°C) ambient temperature range (for operation below 30°F (-1°C) dry air must be used and heat tracing is recommended) Remote position indication options available High actuator cycle life Ease of stem replacement 1/8" NPT air inlet connection standard except Extra Heavy Duty has 3/8" NPT
Specifications Limit Switch Options
Mechanical Weather-proof Mechanical Explosion-proof Proximity, Intrinsically Safe
Specifications Remote On Off
Parker MAN series air-operated needle valves (FC – Fail Close or FO – Fail Open) can be controlled by a 3-way manual air valve or by a low pressure solenoid valve (supplied by others). These can be actuated manually or remotely depending on application requirements. Fail Safe control of the actuators is possible through the use of 3-way manual or solenoid operated valve placed in the pneumatic control line to either Fail Open or Fail Closed actuator. Remote operation increases personnel safety by eliminating the requirement to move adjacent to High Pressure Piping. Please note: Depending on selection of actuator, some applications will require pressure on valve to assist in opening against actuator springs.