The Nova 340 Series Portable Analyzer has been designed for the dueal measurement of O2 and H2 in furnace atmoshpere gases. A built-in sample pump draws in a sample of atmosphere gas where it is detected for oxygen by a long-life oxygen sensor. At the same time, H2 is detected by a long-life thermal conductivity cell.The model 341 is a dual range O2 version that can be switched between the standard range (0-25.0%) and a lower range (0-2.0%) usingthe same sensor. For applications requiring a PPM O2 measurement, a special low range version is available (Model 340L). The models 340 & 341 have rechargeable battery operation, a flow meter, filter, sample hose and dual digital readouts. A recharger is included. Recorder output 4-20mA optional.

Product Specifications

Applications 0
Analysis of oxygen/hydrogen (O2/H2) in exothermic furnace atmospheres for copper, brass or steel anealing, neutral heating, sintering, glass metal beds or oxide coating of steel.
Calibration 0
On air for H2 zero and % O2 span On analyzed mixture of % H2 in N2 for H2 span and O2 zero On analyzed mixture of PPM O2 in N2 for PPM O2 span
Features 0
Rugged modular design that is easy to operate and maintain Fast warm-up and response Long life electrochemical O2 sensor easily detects air infiltration into furnace gas Long-life thermal conductivity cell that provides accurate & stable readings of H2 Separate digital meters with backlight Rechargeable battery operation Built-in sample pump, filter & flow meter Weatherproof (WP) cabinet with clear Lexan cover
Options 0
Recorder outputs of 0-1VDC or 4-20 mA Sample pre-cooler for hot samples Condensate removal for wet applications Suitcase (K) style cabinet available AC only power option O2 and H2 alarms with LED Detachable/portable data logger Dual range O2 (0-25.0% & 0-2.0%)(Model 341WP) Special PPM O2 sensor (100-9999 PPM)(340L)
Specifications Accuracy Repeatability
±2% of full scale
Specifications Alarms
O2 and H2 alarms with LED (optional)
Specifications Ambient Temperature Range
12-50 ºC | 55-120 ºF
Specifications Drift
±1% of full scale per day
Specifications Hazardous Area Rating Options
General Purpose/Non-hazardous
Specifications Linearity
±2% of full scale
Specifications Method Of Detection
Long-life electrochemical O2 sensor, temperature-compensated thermal conductivity (T/C) H2 cell cannot be burned out due to loss of flow or changing gases
Specifications Output Options
4-20 mA or 0-1VDC
Specifications Power
AC/DC operation, 115 VAC 60 Hz for recharging (220 VAC 50Hz available)
Specifications Ranges Available
0-100 to 0-9,999 PPM O2, 0-40.0% H2 (Model 340L) | 0-2.00% and 0-25.0% O2, 0-40.0% H2 (Model 341) | 0-25.0% O2, 0-40.0% H2 (Model 340)
Specifications Resolution
0.1% on % ranges; 1 PPM on PPM O2 range
Specifications Response Time
Less than 10 seconds to 90% step change
Specifications Size Weight
14 1/2" L x 10 1/2" W x 6" H @ 8 lbs (36 x 27 x 18 cm @ 3.6kg)
Unique Applications 0