Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Oxides of Nitrogen, Suitcase (K) Enclosure
Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Oxides of Nitrogen, Suitcase (K) Enclosure
SKU:BYP-5c0eb6
N/A
Regular price
$49.99
Regular price
Sale price
$49.99
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.



The Nova 362 Series are portable analyzers that can provide a detailed analysis of flue gas composition. They have been designed to be accurate, reliable, and easy to use and maintain. Model 362 has customer-replaceable sensors, which respond quickly to the O2, CO, and NOx present in the flue gas sample. The sensor life expectancy is between 3-4 years.In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose, condensate removal filter, secondary filter, flow meter, and then on to the three sensors. The detected O2, CO, and NO are displayed on a digital meter.The Nova 362 can also optionally indicate net stack temperature for doing fuel efficiency calculations (362T). The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.A rechargeable battery provides enough power for about 8 hours of operation and the analyzer can be used while it is being recharged. The battery recharger is included with the analyzer.
Product Specifications
Applications 0
Analysis of oxygen (O 2 ), carbon monoxide (CO), and oxides of nitrogen (NOx as NO). For checking combustion efficiency, air infiltration, NOx emissions, and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial and residential applications.
Calibration 0
Air for O2 span, CO zero and NOx zero Analyzed mixture of CO and NO in nitrogen for CO and NO span and O2 zero
Features 0
Long-life electrochemical sensors for each gas Rugged design that is easy to operate and maintain Fast warm-up and response Digital readout meter Rechargeable battery operation Built-in sample pump, filter, flow meter, and continuous condensate removal Suitcase cabinet (K) is weatherproof when closed Stainless steel probe with sample hose For use on any fuel Rapid CO & NOx reading recovery on 'overdose' Pays for itself in months through fuel savings
Options 0
Recorder output - 4-20mA Stack temperature readout (362T) Special sampling probes Sample pre-cooler Suitcase (K) style cabinet available NOx as NO + NO2 Data-logging to USB stick
Specifications Accuracy Repeatability
<1% of O2; ± 10 PPM CO; ± 3 PPM NOx
Specifications Ambient Temperature Range
0 to 40 ºC | 32 to 105 ºF
Specifications Drift
±2% of full scale per 8 hours of continuous operation
Specifications Hazardous Area Rating Options
General Purpose, Non-Hazardous
Specifications Linearity
±1% of full scale of each gas measured
Specifications Method Of Detection
Customer replaceable electrochemical O2, CO and NO sensor
Specifications Output Options
4-20mA
Specifications Power
115VAC 60Hz for recharging (220VAC 50Hz available)
Specifications Ranges Available
0-200 to 0-2000 PPM NOx (as NO); 0-1800°F (0-1000°C) net stack temperature (362T) | 0-25.0% O2; 0-2000 PPM to 0-4.00% CO (switch selectable)
Specifications Resolution
0.1% O2; 1 PPM on CO and NOx
Specifications Response Time T 90
10-12 seconds for O2; 20-30 seconds for CO and NOx
Specifications Size Weight
approx. 26 x 18 x 13 cm @ 3.4 kg (10" x 7" x 5" @ 7.5lbs)