Portable PPM Oxygen Analyzer
Portable PPM Oxygen Analyzer
SKU:BYS-2891c4
N/A
Regular price
$49.99
Regular price
Sale price
$49.99
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.


The Nova 325 Portable Trace Oxygen Analyzer is designed for accurately measuring trace PPM oxygen in clean, dry sample gas. The customer replaceable electrochemical sensor produces a small output current directly proportional to the amount of O2 in the sample and is capable of measuring trace PPM levels of O2 in any range from 0-100 to 0-9999 PPM. The lowest readable level is 1 PPM. Bypass solenoid valves are used to trap low PPM oxygen in the O2 cell to avoid exposure to ambient air. This allows for a rapid purge down and also protects the cell from momentary over exposure to high O2 levels. A flow control valve and flow meter are provided for regulating the flow of samples under positive pressure. A built-in sample pump is provided for use on samples under atmospheric or slight negative pressure. A rechargeable battery provides enough power for the pump and electronics for about 20 hours of continuous opertion. The analyzer may still be operated while it is being charged. A red LED indicates when to recharge the analyzer and a green LED indicates that it is receiving recharging power. The battery recharger is included with the analyzer.
Product Specifications
Applications 0
For high accuracy analysis of trace PPM oxygen (O2) in non-corrosive process gas.
Calibration 0
Analyzed calibration gas of O2 free nitrogen N2 for zeroAnalyzed calibrationg gas of PPM O2 in N2 for span
Features 0
Rugged design that is light weight, compact and easy to operateFast warm-up and responseAccurately measures PPM O2 in gases including those containing hydrocarbonsany range between 0-100 to 0-9999 PPM availableCustomer replaceable electrochemical 'fuel cell' O2 sensorBlocking solenoid valves used to trap PPM O2 in cell for quick purge down and also protects cell during initial sample line purgeComes complete with flow control valve, filters and flow meterDigital meter readout with backlightRechargeable battery operation
Options 0
Recorder outputs of 0-1V or 4-20 mASampel pre-cooler for hot samplesCondensate removal for wet applicationsBuilt-in sample pump or pressure regulatorAC only power operationO2 alarm with LEDDetachable data loggerType 'K' suitcase style cabinet
Specifications Accuracy Repeatability
±2% of reading
Specifications Alarms
One high or low O2 alarm (optional)
Specifications Ambient Temperature Range
0-50 ºC | 32-122 ºF
Specifications Drift
±1% of full scale per week
Specifications Hazardous Area Rating Options
General Purpose, Non-Hazardous
Specifications Linearity
±2% of full scale
Specifications Method Of Detection
Low range electrochemical O2 sensor
Specifications Output Options
0-1V or 4-20mA (optional)
Specifications Power
AC/DC operation. 115 VAC 60 Hz for recharging (Other voltages available)
Specifications Ranges Available
0-100 PPM to 0-9999 PPM O2
Specifications Resolution
1 PPM
Specifications Response Time T 90
O2 sensor may require an initial purge down from air to low PPM O2, which may last up to 6 hours. After purge down, T-90 response from 1000 to 100 PPM is 30 seconds.
Specifications Size Weight
8" W x 9 1/2" H x 10" D @ 12 lbs. (20 x 23 x 25 cm @ 5.5 kg)
Unique Applications 0
The PPM O2 sensor in Model 325 can be affected by the presence of other gases such as H2S.All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.