The Nova 334 Portable He Analyzer has been designed for the detection of He primarily in air or nitrogen.The thermal conductivity (T/C) cell provides a fast and accurate measurement of He. It has an expected life of over 10 years unless contaminated.In operation, a built in sample pump draws in the gas sample through the probe, filters, flow meter, and on to the T/C cell. The detected He is displayed on a digital readout meter.A rechargeable battery provides power for approximately 8 hours of operation and the analyzer can be used while it is being recharged. The recharger is included.
Product Specifications
Applications 0
For analysis of Helium (He) in a binary gas mixture in process gases such as He in air, He in Nitrogen (N2), He in Carbon Dioxide (CO2), He in Argon (Ar), He in Oxygen (O2), etc.
Calibration 0
Ambient air for zero 100% He calibration gas for span.
Features 0
Rugged design that is easy to operate Fast warm up and response Long-life thermal conductivity cell that provides accurate and stable readings Digital meter readout Modular layout that is easy to maintain Rechargeable battery operated Built in sample pump Lightweight, compact and easy to use Suitcase cabinet (K), weatherproof when closed
Options 0
Recorder output - 4-20mA Sample pre-cooler for hot samples Suitcase (K) style cabinet available
Specifications Accuracy Repeatability
±2% of full scale
Specifications Ambient Temperature Range
12 to 50 ºC | 55 to 120 ºF
Specifications Drift
±1% of full scale per week
Specifications Hazardous Area Rating Options
General Purpose, Non-Hazardous
Specifications Linearity
±2% of F.S. on He in Air
Specifications Method Of Detection
Temperature compensated thermal conductivity (T/C) cell cannot be burned out due to loss of flow or changing gases
Specifications Output Options
4-20mA
Specifications Power
115 VAC / 60 Hz for recharging (220 VAC / 50 Hz available)
Specifications Ranges Available
0-100% He in air or in N2
Specifications Resolution
0.1% of He
Specifications Response Time T 90
90% of final reading in 10 seconds
Specifications Size Weight
K style - approx. 35.5L x 15.2H x 26.6D cm @ 5.5 kg (14" x 6" x 10½" @ 8 lbs)
Unique Applications 0
All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.