The 7460 Series Portable Analyzers are available in six versions for the simultaneous measurement of the gases typically found in the exhaust from internal combustion engines. CO, CO2, and HC's are detected by a dual-wavelength infrared detector. O2 and NOx (as NO) are detected by customer-replaceable electrochemical sensors. If NO2 analysis is selected, this is also by electro-chemical sensor.All detector outputs are displayed on separate front panel digital meters. Optional built in printer, data logger and 4-20 mA recorder outputs are also available.The 7460 Series Analyzers come complete with built in sampling pump, flow meter, automatic condensate removal, filters, PTFE liquid block, 12 ft. (4 m) sampling hose, and stainless steel probe. Also included are a cigarette lighter socket and remote printer actuator button for printer based models.

Product Specifications

Applications 0
For checking engine exhaust emissions for diesel, gasoline, propane, or natural gas powered 2 and 4 cycle engines. Analysis of Carbon Monoxide (CO), Hydrocarbons (HC’s), Carbon dioxide (CO2), Oxygen (O2), Oxides of Nitrogen (NOx), Nitric Oxide (NO), and Nitrogen dioxide (NO2).
Calibration 0
Zero on airSpan on blended gases. NO and NO2 blend to be separate.
Features 0
Rugged design that is easy to operate and maintain Fast warm up and accurate responseLarge digital readouts with back light for each gasSimple to operate, compact sizeSolid state infrared detectors for CO, CO2, and HC'sRechargeable battery operation (recharge from vehicle or from AC adapter)Provided with sample filter, and flexible sample probe with 12 ft. of hose, built in sample pump and automatic condensate removalMeets Bar 97 and OIML specificationsSuitcase (K) style cabinet
Options 0
Analog 4-20 mA outputsBuilt in printer (add 'P' suffix)Data logger for PC computerAdd NO (as NO) to any analyzer (add 'N' suffix)Add NO2 to any analyzer (add 'X' suffix)PPM CO in place of '%' (add 'L' suffix)Bench top (BT) style cabinetWallmount version with active condensate removal (QN4)
Specifications Accuracy Repeatability
±1% of full scale for O2, CO, CO2 and HC's ±2% of full scale for NOx
Specifications Ambient Temperature Range
0 to 40 ºC
Specifications Drift
<±1% in 8 hours after full warmup
Specifications Industry Type
Engine Exhaust
Specifications Linearity
±1.0% of full scale each gas measured
Specifications Method Of Detection
CO (low-range), NO, NO2 and O2 by long life electrochemical sensor. | CO (standard range), CO2, and HC by infrared detector
Specifications Output Options
0-1 VAC | 4-20 mA | Isolated 4-20 mA, RS232, RS485
Specifications Power
115 VAC, 50/60 Hz for recharging | 12 VDC for cigarette lighter socket | 220 VAC, 50/60 Hz for recharging
Specifications Primary Gas To Be Measured
Carbon Monoxide (CO)
Specifications Ranges Available
0-10.00% CO (special low range PPM CO available) | 0-20.0% CO2 | 0-2000 PPM NOx (as NO) | 0-2000 to 0-20,000 PPM HC's (as propane or hexane) | 0-25.0% O2 | 0-800 PPM NO2
Specifications Resolution
0.1% on % gas, 1 PPM on PPM gas
Specifications Response Time T 90
8-10 seconds
Specifications Size Weight
K Style - Approx. 14" W x 6" H x 10 1/2" D (35.5 x 15.2 x 26.6 cm), 12 lbs (5.5 kg)
Specifications Unique Applications
All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.