Scaletron Model 4041 24" Ultra Low Profile Platform Scale
Scaletron Model 4041 24" Ultra Low Profile Platform Scale
SKU:DRU-8e2cfd
Scaletron Model 4041: Corrosion-resistant, high-accuracy platform scale for drums & cylinders.
Regular price
$1,899.99
Regular price
Sale price
$1,899.99
Unit price
per
Delivery via Maden
Expect your order to arrive on time.
Secure Payments
All orders are processed through a secure, PCI-compliant checkout.



The Scaletron Model 4041 24" Ultra Low Profile Platform Scale sets the standard for corrosion resistance and high accuracy in weighing drums and cylinders. With a rugged steel construction and solid PVC decking, this scale ensures safety and ease of handling for off-center loads. It features a 3-1/2 digit LCD display, NEMA 4X, UL-approved enclosure, and a 5-year full warranty. Ideal for institutional and government buyers requiring precision and durability.
Product Specifications
Chemicals Chemicals
Scale is designed to accurately measure weight of alum, ammonia, caustic, fluoride, phosphate, polymers, sodium aluminate, sodium bisulfate, sodium hydroxide, sodium hypochlorite and other liquids or powders.
Digital Controllers Digital Controllers
Indicator Part Number - 3-1/2 DigitPlatform Size - 24" x 24", 30" x 30"Platform Height - 1-3/4 (44 mm)Gross Capacity - Up to 1500 lbs. (680 kg) (150% overload protection is provided)Accuracy - 0.5% of full capacityResolution - 0.1 up to 199.9, or 1.0 over 200 lbs. (kg)4-20 mA - Standard - scale or loop poweredLevel Indication/Relay Contacts - OptionalPower - 85 VAC to 265 VACEnclosure - NEMA 4X , UL Approved EnclosureShipping Weight - 24" x 24" = 130 lbs.; 30" x 30" = 150 lbs.Indicator Part Number - 4-1/2 DigitPlatform Size - 24" x 24", 30" x 30"Platform Height - 1-3/4 (44 mm)Gross Capacity - Up to 1500 lbs. (680 kg) (150% overload protection is provided)Accuracy - 0.5% of full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4-20 mA - Standard - scale or loop poweredLevel Indication/Relay Contacts - (2) StandardPower - 120 VAC, 50/60 Hz, 0.3A 240 VAC, 50/60 Hz, 0.15 AEnclosure - NEMA 4X , UL Approved EnclosureShipping Weight - 24" x 24" = 130 lbs.; 30" x 30" = 150 lbs.Indicator Part Number - 1020â¢Platform Size - 24" x 24", 30" x 30"Platform Height - 1-3/4 (44 mm)Gross Capacity - Up to 1500 lbs. (680 kg) (150% overload protection is provided)Accuracy - 0.1% - 0.25% full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4-20 mA - Standard on Channel 1, Optional on Channel 2 - loop poweredLevel Indication/Relay Contacts - Optional - Up to 4 (as high or low) on one channel or more than one per channel for a total of 4 set points with relay contractPower - 85 VAC to 265 VACEnclosure - NEMA 4X , UL Approved EnclosureShipping Weight - 24" x 24" = 130 lbs.; 30" x 30" = 150 lbs.Indicator Part Number - 1099â¢C.P.C.Platform Size - 24" x 24", 30" x 30"Platform Height - 1-3/4 (44 mm)Gross Capacity - Up to 1500 lbs. (680 kg) (150% overload protection is provided)Accuracy - 0.1% - 0.25% full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4-20 mA - Standard on Channel 1 - loop powered (available for Channels 2 thru 4)Level Indication/Relay Contacts - Optional - Up to 4 (as high or low) on one channel or more than one per channel for a total of 4 set points with relay contractPower - 85 VAC to 265 VACEnclosure - NEMA 4X , UL Approved EnclosureShipping Weight - 24" x 24" = 130 lbs.; 30" x 30" = 150 lbs.
Dimensions Dimension A
24 in | 610 mm
Dimensions Dimension B
29 in | 737 mm
Dimensions Dimension C
24 in | 610 mm
Dimensions Dimension D
24 in | 610 mm
Options Options
240 VAC power (4-1/2 digit display)4-1/2 digit display with active and passive 4 - 20 mA, 0 - 20 mA, and -8 to +12 mA, and two adjustable low level contactsModel 1020⢠5 digit controller with loop powered 4 - 20 mA, up to four adjustable set points and one or two channelsModel 1099⢠Chemical Process ControllerRemote mounting of indicator box up to 200 feet (61 meters) awayJunction box - Additional length of wire cable
Specifications Accuracy
0.1
Specifications Alternating Current Ac Voltage
240 V
Specifications Base Sizes
24 in
Specifications Conductor Wire Cable Size
20 ft
Specifications Enclosure
National Electrical Manufacturer Association (NEMA) 4X | Underwriters Laboratories (UL) Approved
Specifications Gross Capacity Range
0 to 1500 lb | 680 kg
Specifications Industry Standards
European Conformity (CE)
Specifications Number Of Conductors
4
Specifications Warranty
5 Years Full Warranty on All Products!
Specifications Weighing Properties Readout
Kilograms | Pounds
Standard Features Standard Features
Rugged steel construction protected by a corrosion resistant finish, with solid 1/2" PVC deckingUltra-low profile platform design increases safety and ease of drum handlingAccommodates off-center loadsElectronic indicator housed in NEMA 4X, UL approved enclosure to provide protection from acidsNTEP stainless steel temperature compensated load cellSelf-locking tare adjustment knob4 - 20 mA output signal - scale or loop powered
Specifications Specifications
The Drum/Cylinder Scale must have rugged polyester dry powder coated steel frame. Decking shall be solid PVC. All hardware shall be stainless steel to prevent corrosion. There must be a provision for securing weigh frame to floor. The profile shall not exceed 1.75 inches (45 mm) so as not to require a pit or ramp. The load cell must be NTEP approved, stainless steel shear beam cell. Drums and cylinders shall be centered and placed against heavy-duty backstop. Base must be fully electronic with no mechanical lever system to corrode.Scale shall be a Model 4041⢠as manufactured by Scaletron⢠Industries Ltd., Plumsteadville, PA.Standard Indicator3-1/2 Digit LCD Indicator: Indicator must be electronic with digital display with characters 0.5 inches high, with 0.1 lb. or 0.1 kg resolution and housed in a NEMA 4X, UL approved enclosure. Indicator is required to have 4 - 20 mA output selectable as scale powered or loop powered, standard. Indicator must have a knob to set tare weight. Accuracy is 0.5% of full scale, or better.Optional Indicators/Controllers4-1/2 Digit LED indicator: Indicator must be electronic with digital display with characters 0.56 inches high and housed in a NEMA 4X, UL approved enclosure. An output of 4 - 20 mA, 0 - 20 mA, or -8 to + 12 mA, selectable as scale or loop powered to provide versatility to interface with related equipment, must be standard equipment. Indicator comes with two low level relay contacts, standard. A knob to set tare weights is required. Indicator must be capable of 0.1 lb. or 0.1 kg up to 1000.0 lbs. or kg. Accuracy is 0.5% of full scale, or better.Model 1020⢠5 Digit Controller: Controller must be electronic with a two line, backlit alphanumeric digital display and housed in a NEMA 4X, UL approved enclosure. Available as single or dual channel and capable of displaying two channels simultaneously. A loop powered programmable output of 4 - 20 mA and four set points per channel must be standard equipment. Indicator must be capable of 0.1 lb. or 0.1 kg up to 1500 lbs. or 680.4 kg. Accuracy is 0.25% of full scale, or better.