Skip to product information
1 of 3
Scaletron Industries, Ltd. →

Scaletron Model 4042-52 Spill Containment Tank Scales

Scaletron Model 4042-52 Spill Containment Tank Scales

SKU:SPI-dd0a77

Accurately display chemical weights with Scaletron Model 4042-52 Spill Containment Scales. Corrosion-resistant design meets EPA, CE, and OSHA standards.

Regular price $2,899.00
Regular price Sale price $2,899.00
Sale

Initiate Order

Scaletron Model 4042-52 Spill Containment Tank Scales

Scaletron Model 4042-52 Spill Containment Tank Scales

$2,899.00

Quantity: 1

Claim Your Seller Account

Scaletron Model 4042-52 Spill Containment Tank Scales

Scaletron Model 4042-52 Spill Containment Tank Scales

$2,899.00

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Scaletron Model 4042-52 Spill Containment Tank Scales are designed to accurately display the weight of chemicals not yet dispensed, with a rugged steel construction and polyethylene basin for containment. These scales meet EPA, CE, and OSHA standards, ensuring corrosion resistance and reliable performance. With features like a 4-20 mA output, NEMA 4X enclosure, and 5-year warranty, these scales provide precise measurements and durability for industrial applications.

Ready to Grow Without Cash Flow Constraints?

Get Net 30, 60, or 90 day terms at 0% interest on any purchase

Ready to Grow Without Cash Flow Constraints?

Product Specifications

Additional Information Additional Information
Meets secondary spill containment requirements by the EPA, OSHA, and other local agenciesStandard base sizes w/out bladder 52" x 52" - other sizes availableHigh accuracy of ±0.1% to 0.5%Standard indicator: 3-1/2 digit LCD display with easy readability to 1 lb. (kg), 0.1lb (kg)
Chemicals Chemicals
Scale is designed to accurately measure weight of alum, ammonia, caustic, fluoride, phosphate, polymers, sodium aluminate, sodium bisulfate, sodium hydroxide, sodium hypochlorite and other liquids or powders
Digital Controllers Digital Controllers
Indicator - 3-1/2 DigitPlatform Size & (Containment Capacities) - 52" x 52" (62 gal.) - other sizes availablePlatform Height - 3-1/2 inch high (88.0 mm)Gross Capacity - Up to 6000 lbs. (2726 kg) - other capacities available (150% overload protection is provided)Accuracy - 0.5% of full capacityResolution - 0.1 up to 199.9, or 1.0 over 200 lbs. (kg)4-20 mA - Standard - scale or loop poweredLevel Indication/ Relay Contacts - OptionalPower - 85 VAC to 265 VACEnclosure - NEMA 4X, UL Approved EnclosureShipping Weight - 234 lbsIndicator - 4-1/2 DigitPlatform Size & (Containment Capacities) - 52" x 52" (62 gal.) - other sizes availablePlatform Height - 3-1/2 inch high (88.0 mm)Gross Capacity - Up to 6000 lbs. (2726 kg) - other capacities available (150% overload protection is provided)Accuracy - 0.5% of full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4-20 mA - Standard - scale or loop poweredLevel Indication/ Relay Contacts - (2) StandardPower - 120VAC, 50/60 Hz, 0.3A and 240VAC, 50/60Hz, 0.15AEnclosure - NEMA 4X, UL Approved EnclosureShipping Weight - 234 lbsIndicator - 1020™Platform Size & (Containment Capacities) - 52" x 52" (62 gal.) - other sizes availablePlatform Height - 3-1/2 inch high (88.0 mm)Gross Capacity - Up to 6000 lbs. (2726 kg) - other capacities available (150% overload protection is provided)Accuracy - 0.01%-0.25% full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4-20 mA - Standard on Channel 1, Optional on Channel 2 - loop poweredLevel Indication/ Relay Contacts - Optional - Up to 4 (as high or low) on one channel or more than one per channel for a total of 4 set points with relay contractPower - 85VAC to 265VACEnclosure - NEMA 4X, UL Approved EnclosureShipping Weight - 234 lbsIndicator - 1099™C.P.C.Platform Size & (Containment Capacities) - 52" x 52" (62 gal.) - other sizes availablePlatform Height - 3-1/2 inch high (88.0 mm)Gross Capacity - Up to 6000 lbs. (2726 kg) - other capacities available (150% overload protection is provided)Accuracy - 0.01%-0.25% full capacityResolution - 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg)4-20 mA - Standard on Channel 1 - loop powered (available for Channels 2 thru 4)Level Indication/ Relay Contacts - Optional - Up to 4 (as high or low) on one channel or more than one per channel for a total of 4 set points with relay contractPower - 85VAC to 265VACEnclosure - NEMA 4X, UL Approved EnclosureShipping Weight - 234 lbs
Note Note
Made in USA.
Options Options
240 VAC power (4-1/2 digit display)4-1/2 digit display with active and passive 4-20 mA, 0-20 mA, and -8 to +12 mA, and two adjustable low level contactsModel 1020™ 5 digit controller with loop powered 4-20 mA, up to four adjustable set points and one or two channelsModel 1099™ Chemical Process ControllerRemote mounting of indicator box up to 200 feet (61 meters) awayJunction box - Additional length of wire cable
Specifications Accuracy
0.1 to 0.5 %
Specifications Alternating Current Ac Voltage
240 V
Specifications Base Length
52 in
Specifications Base Width
52 in
Specifications Cable Length
20 ft
Specifications Display Type
Liquid Crystal Display (LCD)
Specifications Gross Capacity Range
0 to 6000 lb | 2726 kg
Specifications Industry Standards
Environmental Protection Agency (EPA) | European Conformity (CE) | Occupational Safety and Health Administration (OSHA)
Specifications Number Of Conductors
4
Specifications Output Current
4 to 20 mA
Specifications Warranty
5 Years Full Warranty on All Products!
Standard Features Standard Features
Rugged steel construction protected by corrosion resistant finish, with polyethylene containment basinFour load cell design means the load can be placed anywhere on the containment platform and does not need to be leveledElectronic indicator housed in NEMA 4X, UL approved enclosure to provide protection from acidsLoad cells are mounted outside of spill containment basin to eliminate damage due to chemical spills.Self-locking tare adjustment knob4-20 mA output - scale or loop powered20 ft. of 4 conductor wire cable
Specifications Specifications
The Integral Splash, Spill & Containment Scale must have rugged steel frame and shall be dry powder polyester plastic coated. The integral containment deck and basin shall be solid polyethylene. All hardware must be stainless steel. Scale frame height shall not exceed 1.5". Total height depends on containment capacity. Load cells must be sealed in gasketed PVC enclosure. All 4 load cells shall be located outside the chemical containment basin to eliminate damage due to chemical spills. Indicator must be electronic with digital readout and housed in a NEMA 4X, UL approved fiberglass enclosure. There shall be a 4-20 mA output signal.Scale shall be a Model 4042-52™ as manufactured by Scaletron™ Industries Ltd., Plumsteadville, PA.Standard Indicator:3-1/2 Digit LCD Indicator: Indicator must be electronic with digital display with characters 0.5 inches high, with 0.1 lb. or 0.1 kg resolution and housed in a NEMA 4X, UL approved enclosure. Indicator is required to have 4-20 mA output selectable as scale powered or loop powered, standard. Indicator must have a knob to set tare weight. Accuracy is 0.5% of full scale, or better.Optional Indicators:4-1/2 Digit LED indicator: Indicator must be electronic with digital display with characters 0.56 inches high and housed in a NEMA 4X, UL approved enclosure. An output of 4-20 mA, 0-20 mA, or -8 to + 12 mA, selectable as scale or loop powered to provide versatility to interface with related equipment, must be standard equipment. Indicator comes with two low level relay contacts, standard. A knob to set tare weights is required. Indicator must be capable of 0.1 lb. or 0.1 kg up to 1000.0 lbs. or kg. Accuracy is 0.5% of full scale, or better.Model 1020™ 5 Digit Controller: Controller must be electronic with a two line, backlit alphanumeric digital display and housed in a NEMA 4X, UL approved enclosure. Available as single or dual channel and capable of displaying two channels simultaneously. A loop powered programmable output of 4-20 mA and four set points per channel must be standard equipment. Indicator must be capable of 0.1 lb. or 0.1 kg up to 6000 lbs. or 2726 kg. Accuracy is 0.25% of full scale, or better.