National Compressor Exchange, Inc. →

Trane CRHR Reciprocating Compressor

Trane CRHR Reciprocating Compressor

SKU:COM-ba73bf

High-performance Trane CRHR Reciprocating Compressor for industrial applications.

Regular price $3,999.99
Regular price Sale price $3,999.99
Sale

Initiate Order

Trane CRHR Reciprocating Compressor

Trane CRHR Reciprocating Compressor

$3,999.99

Quantity: 1

Claim Your Seller Account

Trane CRHR Reciprocating Compressor

Trane CRHR Reciprocating Compressor

$3,999.99

Quantity: 1

Delivery via Maden

Expect your order to arrive on time.

Secure Payments

All orders are processed through a secure, PCI-compliant checkout.

View full details
The Trane CRHR Reciprocating Semi-Hermetic Compressor is a high-performance compressor designed for industrial applications. With a Cu. In. Display of 102.08, 4 cylinders, and the capability to handle 26 tons, this compressor delivers reliable cooling power. Weighing 815 lb, it is robust and durable. The compressor is cataloged as TRN249 and comes with a suction line filter for system cleanliness and TRN-1044-U unloaders as accessories. With a recommended evacuation and dehydration process, this compressor ensures optimal system performance and longevity.

Product Specifications

Accessories Accessories
TRN-1044-U, Unloaders
Evacuation Procedure 0
System Cleanliness System cleanliness is one of the most important factors that affect system and compressor reliability. System contamination can cause both mechanical and electrical failures. There are several sources ofsystem contamination. Some of these are: Copper oxides from system refrigerant piping brazing. Refrigerant piping chips and burrs and brazing flux. Processing residue and metal chips from evaporators and condensers. Metal chips and wire brush strands from processing of other system components. Contamination in refrigeration tubing which is left uncapped during assembly. Moisture and air. In addition, field erected systems are subject to all the dirt and system contamination of the typical jobsite. It is recommended that a suction line filter be installed in the system to prevent contaminants form entering the compressor ; Evacuation and Dehydration For the refrigeration system to work property, it must be free of air and moisture. The process by which air and moisture are removed is known as evacuation and dehydration. Moisture and air are harmful to the system because they increase the condensing temperature, raise the discharge gas temperature, cause oil breakdown and the formation of acids. Acids are corrosive to the components in the refrigeration system, including the piping, refrigerant specialties, and the which can cause mechanical failure of the compressor.The recommended method for evacuation and dehydration is to evacuate the system from both the gigh and low sides to 800 microns or less. To establish that the unit is leakfree and moisture-free, a standing vacuum test is recommended. The maximum allowable rise over a 15 minute period is 200 microns. If the Hse exceeds this, either there is still moisture in teh system or a leak is present in the system See Chart 1.CAUTIONNEVER USE OXYGEN OR ACETYLENE IN PLACE OF REFRIGERANT AND DRY NITROGEN FOR LEAK TESTING. A VIOLENT EXPLOSION MAY RESULT, CAUSING PERSONAL INJURY OR DEATH.ALWAYS USE A PRESSURE REGULATOR WHEN USING NITROGEN TO PRESSURE TEST. FAILURE TO DO SO WILL RESULT IN EXTREMELY HIGH PRESSURE WHICH COULD EXCEED THE BURST PRESSURE OF TEH COMPRESSOR OR OTHER SYSTEM COMPONENTS AND RESULT IN PERSONAL INJURY OR DEATH.FOR SHELF STORAGE EVAC. TO 250 MICRONS
Specifications Catalog Number
TRN249
Specifications Cu In Display
102.08
Specifications No Of Cylinders
4
Specifications Tons
26
Specifications Weight
815 lb